Programmable Power Meter / Regular Resolution Model 2014
¡@
All-Bright 2010 Series Regular Resolution Power Meter, there are 3 voltage ranges, 3 current ranges, and 9 watt ranges selectable. With proper resolution, All-Bright offers you excellent quality and most economic solution for power measuring. It can be widely used in a variety of fields from home appliance, office automatic machines, to facilities of the industry. Flexible and user friendly design, easy for operation, All-Bright sees your needs.
¡@
¡@
¡@
FEATURES
¡@
¡DBasic
¡Ó0.1% accuracy.
¡DV, A, W true RMS measurement.
¡DProvides auto and manual ranging for both voltage and current measurements.
¡DProvides autoranging for measurements of frequency.
¡D4-1/2 digits A/D converter is used, provides high accuracy, resolution, and
stability.
¡DProvides 3 multi-function displays with 7 selectable measurement modes (Wrms,
Arms, Wrms, PF, VA, VAR, Hz).
¡D3
ranges for voltage measurements, 3 ranges for current measurements, and 9 ranges
for Watt measurements.
¡DAutomatically store the latest operating settings before powered-off. Resume
the settings on the next power-on.
¡DPeak current over-range warning.
¡@¡@*** Features listed below are only for Model 2011/14/15
¡DProvides PT and CT ratio-multiplication function (between 0.0010 and 1000.0).
¡DIndependent comparison function for each display.
¡DFront Panel Store / Recall Function
¡DAverage Display Function
¡DDisplay Hold Function
¡DStandard RS-232C Interface
SPECIFICATIONS
INPUT
Item
|
Voltage
|
Current
|
Input Circuit Type | Resistive voltage divider | Shunt input |
Rated Input (range rms) |
2011/15: 30/300/600V |
2011: 30mA/300mA/3A |
Input Impedance | Approx. 1M£[ |
2011: Approx. 66.7 m£[ |
Max. Input (at 50/60Hz) | 600Vrms |
2011: 3Arms/ 9Apeak |
Range Selection | 2012 : Auto Range, 2011/14/15 : Manual or Auto with LED Indicated | |
A/D Conversion | 4 1/2 Digits ADC | |
Input Filter | 2012 : None, 2011/14/15 : 1KHz low pass Filter | |
Input Terminal | 2011/12/14: Screw Terminal, 2015: Binding Post Terminal |
¡@
¡@
MEASUREMENT FUNCTION
Item
|
Voltage / Current
|
Effective Power
|
Frequency Range | 2011/12: 10Hz to 20KHz, 2014 : 10Hz to 50KHz, 2015: 10Hz to 5KHz | |
Crest Factor | ¡§3¡¨ at Rated Input | |
Operating Principle | Ture rms | |
Display
Accuracy |
¡@
0.15%
of rng + 0.2% of rdg |
¡@
0.2% of
rng + 0.2% of rdg 0.15% of rng + 0.2% of rdg+( 0.5%*(f-10KHz)) |
Effective Input Range | 5% to 100% of Set Range | |
Temp. Coefficient | ¡Ó0.05% of Range/¢J | |
Display Update Rate | 3.3 times/sec | |
Display Digits | 4 1/2 Digits (20000 counts) | Full 4 Digits (10000 counts) |
¡@
¡@
FREQUEYCY MEASUREMENT FUNCTION
Operating Principle
|
Reciprocal Counting Method
|
Display Digits
|
Full 5 digits display on each frequency
|
Display Range
|
10.000Hz to 100.00KHz
|
Display Resolution
|
1mHz to 10Hz
|
Display Accuracy
|
¡Ó (0.006%+5d)
|
Frequency Range
|
10Hz to 100KHz
|
Measurement Range
|
5% to 100% of Rated Range
|
¡@
¡@
COMPUTING FUNCTION
Item
|
Wrms
|
VA
|
VAR
|
PF
|
Computation
|
W
|
VA=V*A
|
VAR=
|
PF=W/(V*A)
|
Computation Range
|
Depends on the Selected V and A
Range
|
-1 to 0 to 1
|
||
Computation Accuracy
|
----
|
¡Ó0.05% of VA Range
|
¡Ó0.05% of VA Range
|
¡Ó0.001
|
Maximum Display
|
9999
|
9999
|
9999
|
¡Ó1.000
|
¡@
¡@
**Below Function Only for Model 2011/14/15
Display Scaling Function | Reassign Ratio: 0.0010 to 1000.0 |
Significant Digits | Selected Automatically According to Significant Digits in the Voltage and Current |
Averaging Function | Display Computing Average (Fixed 3 Measured) |
Compare Function | Independent Compare with HI/GO/LO LED Display for Each Display |
¡@
¡@
General Specification
Interface | Standard RS-232C Interface on model 2011/14/15 |
Power Supply | AC 115V/230V¡Ó10%, 60Hz/50Hz Switch Selectable |
Warm-up Time | Approx. 30min. |
Operation Humidity / Temperature Range | 80% R.H. (+5¢J ~ 30¢J), 50% R.H. (+31¢J ~ 40¢J) |
Storage Temperature / Humidity Range | -10 ~ 70¢J, <80% R.H. |
Accessories | Power Cord x 1, Operation Manual x 1 |
¡@