66000A Modular Power System

Agilent 6692A 6600 W系統電源供應器,60 V,110 A

High density: eight slots in 7 inches of rack space
Output sequencing
Low ripple and noise
High-accuracy read-back of voltage and current over GPIB

Standard Commands for Programmable Instruments (SCPI)

Optional keyboard and display unit
Serial link to connect two mainframes at one GPIB address
Optional isolation and polarity-reversal relays
Built-in self-test
For complete details, click on the Data Sheet link
 

 

The Agilent 66000A modular power system simplifies test-system assembly, cabling programming, debugging, and operation. It is ideal for ATE and production test environments, where it can supply bias power and stimulus to subassemblies and final products. The Agilent modular power system saves rack space. The 66000A 7-in high (4-EIA units) mainframe can accommodate up to eight dc power modules.
 

Modular Power System: 1200 W per mainframe GPIB

Specifications

(at 0° to 55°C unless otherwise specified)

66101A 66102A 66103A 66104A 66105A 66106A
Output ratings at 40°C
Output voltage      0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V 0 to 200 V
Output current     0 to 16 A 0 to 7.5 A 0 to 4.5 A 0 to 2.5 A 0 to 1.25 A 0 to 0.75 A
Maximum power     128 W 150 W 150 W 150 W 150 W 150 W
 
Programming accuracy at 25°C ±5°C
Voltage       0.03% + 3 mV 8 mV 13 mV 27 mV 54 mV 90 mV
Current    0.03% + 6 mA 3 mA 2 mA 1.2 mA 0.6 mA 0.4 mA
 
Readback accuracy (via GPIB or keyboard display at 25°C ±5°C)
Voltage   0.02%+ 2 mV 5 mV 8 mV 16 mV 32 mV 54 mV
Current       0.02%+ 6 mA 3 mA 2 mA 1 mA 0.6 mA 0.3 mA
 
Ripple and noise (20 Hz to 20 MHz)
Constant Voltage rms      2 mV 3 mV 5 mV 9 mV 18 mV 30 mV
peak-peak      5 mV 7 mV 10 mV 15 mV 25 mV 50 mV
Constant Current rms      8 mA 4 mA 2 mA 1 mA 1 mA 1 mA
               
Line regulation
Voltage      0.5 mV 0.5 mV 1 mV 2 mV 3 mV 5 mV
Current      0.75 mA 0.5 mA 0.3 mA 0.1 mA 50 µA 30 µA
               
Load regulation
Voltage      1 mV 1 mV 1 mV 2 mV 4 mV 7 mV
Current      0.5 mA 0.2 mA 0.2 mA 0.1 mA 50 µA 30 µA

Transient response time

 

 

Less than 1 ms for the output voltage to recover within 100 mV
of its previous level following any step change in load current
up to 10 percent of rated current

Supplemental Characteristics (Non-warranted characteristics determined by design that are
useful in applying the product)
               
Average resolution
Voltage      2.4 mV 5.9 mV 10.4 mV 18.0 mV 36.0 mV 60.0 mV
Current     4.6 mA 2.3 mA 1.4 mA 0.75 mA 0.39 mA 0.23 mA
Output voltage programming (OVP)      50 mV 120 mV 200 mV 375 mV 750 mV 1.25 mV
OVP accuracy        250 mV 500 mV 800 mV 1 V 1.5 V 2.5 V
               
Modular Power System: 1200 W per mainframe GPIB (Continued)

Specifications
(at 0° to 55°C unless otherwise
 specified)

66101A - J03

Special Order

Option

66101A - J05

Special Order

Option

66102A - J05

Special Order 

Option

66103A - J01

Special Order

Option

66103A - J02

Special Order

Option

 
Output ratings at 40°C
Output voltage      5.7 V 12 V 15 V 37 V 40 V
Output current       20 A 12 A 10 A 4.5 A 3.6 A
Maximum power       114 W 144 W 150 W 167 W 144 W
             
Programming accuracy at 25°C ±5°C
Voltage      0.03% + 2.5 mV 5 mV 8 mV 13 mV 15 mV
Current      0.03% + 8 mA 6 mA 4 mA 2 mA 2 mA
             
Readback accuracy (via GPIB keyboard display at 25°C ±5°C)
Voltage     0.02% + 2 mV 3 mV 5 mV 8 mV 9.2 mV
Current      0.02% + 8 mA 6 mA 4 mA 2 mA 2 mA
             
Ripple and noise (20 Hz to 20 MHz)
Constant Voltage rms     2 mV 3 mV 3 mV 5.3 mV 6 mV
peak-peak       5 mV 7 mV 7 mV 10.6 mV 11.5 mV
Constant Current rms     10 mA 8 mA 6 mA 2 mA 2 mA
             
Line regulation
Voltage      0.5 mV 0.5 mV 0.5 mV 1 mV 1 mV
Current       0.5 mA 0.75 mA 0.5 mA 0.3 mA 0.3 mA
             
Load regulation
Voltage       1 mV 1 mV 1 mV 1 mV 1 mV
Current       1 mA 0.5 mA 0.3 mA 0.2 mA 0.2 mA

Transient response time

 

 

Less than 1 ms for the output voltage to recover within 100 mV of its
previous level following any step change in load current up to 10 percent
of rated current

Supplemental Characteristics (Non-warranted characteristics determined by design that 
are useful in applying the product)
 
             
Average resolution
Voltage       2 mV 3.6 mV 4.5 mV 11 mV 12 mV
Current     6 mA 4.6 mA 3.1 mA  1.4 mA 1.2 mA
OVP       45 mV 75 mV 90 mV 200 mV 230 mV
OVP accuracy   250 mV 375 mV 375 mV 850 mV 920 mV
             
Modular Power System: 1200 W per mainframe GPIB (Continued)

Specifications
(at 0° to 55°C unless otherwise specified)
 

66103A - J09
Special Order

Option

66103A-J12

Special Order

Option

66104A -J09

Special Order

Option

66105A - J01

Special Order

Option

Output ratings at 40°C
Output voltage    28.5 V 24 V 55 V 35 V
Output current    5.5 A 6 A 3 A 1.25 A
Maximum power    157 W 144 W 165 W 44 W
Programming accuracy at 25°C ±5°C
Voltage     0.03% + 13 mV 13 mV 25 mV 15 mV
Current     0.03% + 3 mA 3 mA 1.5 mA 0.6 mA
Readback accuracy (via GPIB or keyboard display at 25°C ±5°C)
Voltage     0.02% + 8 mV 8 mV 15 mV 9 mV
Current     0.02% + 3 mA 3 mA 1.2 mA 0.6 mA
Ripple and noise (20 Hz to 20 MHz)
Constant Voltage rms    5 mV 5 mV 9 mV 6 mV
peak-peak    10 mV 10 mV 15 mV 11.5 mV
Constant Current rms    4 mA 4 mA 1.2 mA 1 mA
Line regulation
Voltage    1 mV 1 mV 2 mV 1 mV
Current    0.3 mA 0.3 mA 0.1 mA 50 µA
Load regulation
Voltage    1 mV 1 mV 2 mV 1 mV
Current    0.2 mA 0.2 mA 0.1 mA 50 µA

Transient response time

 

 

Less than 1 ms for the output voltage to recover within 100 mV of its
previous level following any step change in load current up to 
10 percent  of rated current

Supplemental Characteristics

(Non-warranted characteristics determined  by
design that are useful in applying the product) 

Average resolution
Voltage    10.4 mV 8 mV 16.5 mV 2 mV
Current    2 mA 2 mA 0.9 mA 1.2 mA
OVP    200 mV 150 mV 350 mV 230 mV
OVP accuracy    800 mV 600 mV 950 mV 920 mV