66000A Modular Power System
|
High density:
eight slots in 7 inches of rack space Standard Commands for Programmable Instruments (SCPI)
Optional
keyboard and display unit |
The Agilent 66000A modular power
system simplifies test-system assembly, cabling programming, debugging, and
operation. It is ideal for ATE and production test environments, where it can
supply bias power and stimulus to subassemblies and final products. The Agilent
modular power system saves rack space. The 66000A 7-in high (4-EIA units)
mainframe can accommodate up to eight dc power modules.
Modular Power System: 1200 W per mainframe GPIB | |||||||
Specifications (at 0° to 55°C unless otherwise specified) |
66101A | 66102A | 66103A | 66104A | 66105A | 66106A | |
Output ratings at 40°C | |||||||
Output voltage | 0 to 8 V | 0 to 20 V | 0 to 35 V | 0 to 60 V | 0 to 120 V | 0 to 200 V | |
Output current | 0 to 16 A | 0 to 7.5 A | 0 to 4.5 A | 0 to 2.5 A | 0 to 1.25 A | 0 to 0.75 A | |
Maximum power | 128 W | 150 W | 150 W | 150 W | 150 W | 150 W | |
Programming accuracy at 25°C ±5°C | |||||||
Voltage | 0.03% + | 3 mV | 8 mV | 13 mV | 27 mV | 54 mV | 90 mV |
Current | 0.03% + | 6 mA | 3 mA | 2 mA | 1.2 mA | 0.6 mA | 0.4 mA |
Readback accuracy (via GPIB or keyboard display at 25°C ±5°C) | |||||||
Voltage | 0.02%+ | 2 mV | 5 mV | 8 mV | 16 mV | 32 mV | 54 mV |
Current | 0.02%+ | 6 mA | 3 mA | 2 mA | 1 mA | 0.6 mA | 0.3 mA |
Ripple and noise (20 Hz to 20 MHz) | |||||||
Constant Voltage rms | 2 mV | 3 mV | 5 mV | 9 mV | 18 mV | 30 mV | |
peak-peak | 5 mV | 7 mV | 10 mV | 15 mV | 25 mV | 50 mV | |
Constant Current rms | 8 mA | 4 mA | 2 mA | 1 mA | 1 mA | 1 mA | |
Line regulation | |||||||
Voltage | 0.5 mV | 0.5 mV | 1 mV | 2 mV | 3 mV | 5 mV | |
Current | 0.75 mA | 0.5 mA | 0.3 mA | 0.1 mA | 50 µA | 30 µA | |
Load regulation | |||||||
Voltage | 1 mV | 1 mV | 1 mV | 2 mV | 4 mV | 7 mV | |
Current | 0.5 mA | 0.2 mA | 0.2 mA | 0.1 mA | 50 µA | 30 µA | |
Transient response time
|
Less than 1 ms for
the output voltage to recover within 100 mV |
||||||
Supplemental Characteristics |
(Non-warranted characteristics determined by design that are useful in applying the product) |
||||||
Average resolution | |||||||
Voltage | 2.4 mV | 5.9 mV | 10.4 mV | 18.0 mV | 36.0 mV | 60.0 mV | |
Current | 4.6 mA | 2.3 mA | 1.4 mA | 0.75 mA | 0.39 mA | 0.23 mA | |
Output voltage programming (OVP) | 50 mV | 120 mV | 200 mV | 375 mV | 750 mV | 1.25 mV | |
OVP accuracy | 250 mV | 500 mV | 800 mV | 1 V | 1.5 V | 2.5 V | |
Modular Power System: 1200 W per mainframe GPIB (Continued) | ||||||
Specifications |
66101A - J03 Special Order Option |
66101A - J05 Special Order Option |
66102A - J05 Special Order Option |
66103A - J01 Special Order Option |
66103A - J02 Special Order Option |
|
Output ratings at 40°C | ||||||
Output voltage | 5.7 V | 12 V | 15 V | 37 V | 40 V | |
Output current | 20 A | 12 A | 10 A | 4.5 A | 3.6 A | |
Maximum power | 114 W | 144 W | 150 W | 167 W | 144 W | |
Programming accuracy at 25°C ±5°C | ||||||
Voltage | 0.03% + | 2.5 mV | 5 mV | 8 mV | 13 mV | 15 mV |
Current | 0.03% + | 8 mA | 6 mA | 4 mA | 2 mA | 2 mA |
Readback accuracy (via GPIB keyboard display at 25°C ±5°C) | ||||||
Voltage | 0.02% + | 2 mV | 3 mV | 5 mV | 8 mV | 9.2 mV |
Current | 0.02% + | 8 mA | 6 mA | 4 mA | 2 mA | 2 mA |
Ripple and noise (20 Hz to 20 MHz) | ||||||
Constant Voltage rms | 2 mV | 3 mV | 3 mV | 5.3 mV | 6 mV | |
peak-peak | 5 mV | 7 mV | 7 mV | 10.6 mV | 11.5 mV | |
Constant Current rms | 10 mA | 8 mA | 6 mA | 2 mA | 2 mA | |
Line regulation | ||||||
Voltage | 0.5 mV | 0.5 mV | 0.5 mV | 1 mV | 1 mV | |
Current | 0.5 mA | 0.75 mA | 0.5 mA | 0.3 mA | 0.3 mA | |
Load regulation | ||||||
Voltage | 1 mV | 1 mV | 1 mV | 1 mV | 1 mV | |
Current | 1 mA | 0.5 mA | 0.3 mA | 0.2 mA | 0.2 mA | |
Transient response time
|
Less than 1 ms for
the output voltage to recover within 100 mV of its |
|||||
Supplemental Characteristics |
(Non-warranted characteristics determined by design that are useful in applying the product) |
|||||
Average resolution | ||||||
Voltage | 2 mV | 3.6 mV | 4.5 mV | 11 mV | 12 mV | |
Current | 6 mA | 4.6 mA | 3.1 mA | 1.4 mA | 1.2 mA | |
OVP | 45 mV | 75 mV | 90 mV | 200 mV | 230 mV | |
OVP accuracy | 250 mV | 375 mV | 375 mV | 850 mV | 920 mV | |
Modular Power System: 1200 W per mainframe GPIB (Continued) | |||||
Specifications |
66103A - J09 Option |
66103A-J12 Special Order Option |
66104A -J09 Special Order Option |
66105A - J01 Special Order Option |
|
Output ratings at 40°C | |||||
Output voltage | 28.5 V | 24 V | 55 V | 35 V | |
Output current | 5.5 A | 6 A | 3 A | 1.25 A | |
Maximum power | 157 W | 144 W | 165 W | 44 W | |
Programming accuracy at 25°C ±5°C | |||||
Voltage | 0.03% + | 13 mV | 13 mV | 25 mV | 15 mV |
Current | 0.03% + | 3 mA | 3 mA | 1.5 mA | 0.6 mA |
Readback accuracy (via GPIB or keyboard display at 25°C ±5°C) | |||||
Voltage | 0.02% + | 8 mV | 8 mV | 15 mV | 9 mV |
Current | 0.02% + | 3 mA | 3 mA | 1.2 mA | 0.6 mA |
Ripple and noise (20 Hz to 20 MHz) | |||||
Constant Voltage rms | 5 mV | 5 mV | 9 mV | 6 mV | |
peak-peak | 10 mV | 10 mV | 15 mV | 11.5 mV | |
Constant Current rms | 4 mA | 4 mA | 1.2 mA | 1 mA | |
Line regulation | |||||
Voltage | 1 mV | 1 mV | 2 mV | 1 mV | |
Current | 0.3 mA | 0.3 mA | 0.1 mA | 50 µA | |
Load regulation | |||||
Voltage | 1 mV | 1 mV | 2 mV | 1 mV | |
Current | 0.2 mA | 0.2 mA | 0.1 mA | 50 µA | |
Transient response time
|
Less than 1 ms for
the output voltage to recover within 100 mV of its |
||||
Supplemental Characteristics |
(Non-warranted
characteristics determined by |
||||
Average resolution | |||||
Voltage | 10.4 mV | 8 mV | 16.5 mV | 2 mV | |
Current | 2 mA | 2 mA | 0.9 mA | 1.2 mA | |
OVP | 200 mV | 150 mV | 350 mV | 230 mV | |
OVP accuracy | 800 mV | 600 mV | 950 mV | 920 mV | |