D.C. POWER SUPPLY
¡@
SPECIFICATIONS |
|
OPERATION MODE | |
Independent | Two independent outputs and 5V fixed output |
Output from 0 to rating volts and 0 to rating amperes | |
Series | Output from 0 to ¡Ó rating volts at rating amperes each |
Output from 0 to double rating volts at rating amperes | |
Parallel | Output from 0 to double rating amperes at rating volts |
¡@ | |
5V FIXED OUTPUT | |
Regulation | Line regulation < 5mV |
Load regulation < 10mV | |
Ripple & Noise | < 2mVrms |
Voltage Accuracy | 5V ¡Ó 0.25V |
Output Current | 3A |
¡@ | |
TRACKING OPERATION | |
Tracking Error | < 0.5% + 10mV of the master |
Series Regulation | < 300mV |
¡@ | |
CONSTANT VOLTAGE OPERATION | |
Regulation | Line
regulation < 0.01% + 3mV |
Load regulation < 0.01% + 5mV (rating current < 10A) < 0.02% + 3 5mV (rating current > 10A) |
|
Ripple & Noise | < 1mVrms 5Hz ~ 1MHz |
Recovery Time | < 100µS (50% Load change, Minimum load 0.5A) |
¡@ | |
CONSTANT CURRENT OPERATION | |
Regulation | Line regulation < 0.2% + 3mA |
Load regulation < 0.2% + 3mA | |
Ripple Current | < 3mArms |
¡@ | |
METER | |
Analog | V-meter and I-meter each one |
2.5 class | |
Dimension 50 x 50 mm | |
Digital | 3 1/2 digits 0.5" LED display |
Accuracy ¡Ó (0.5% of rdg + 2 digits) | |
¡@ | |
INSULATION | |
Chassis and Terminal | 100M£[ or above ( DC 1000V ) |
Chassis and AC Cord | 100M£[ or above ( DC 1000V ) |
¡@ | |
POWER SOURCE | |
AC 100V/120V/220V/240V¡Ó10%, 50/60Hz | |
¡@ | |
ACCESSORIES | |
Instruction
manual x 1,
Power cord x 1,
¡@ For: GPQ, GPR, GPS, GPC, PPE, PPS, PPT, PSS, PST (Current 3A)
|
|
¡@ | |
DIMENSIONS | |
255(W) x 145(H) x 420(D) mm |
¡@
SELECTION GUIDE |
||||
¡@ | Model | Independent | Series | Parallel |
Analog |
GPC-3060 | 0~30V x 2, 0~6A x 2 | 60V 6A | 30V 12A |
GPC-6030 | 0~60V x 2, 0~3A x 2 | 120V 3A | 60V 6A | |
Digital |
GPC-6030D | 0~60V x 2, 0~3A x 2 | 120V 3A | 60V 6A |
GPC-3060D | 0~30V x 2, 0~6A x 2 | 60V 6A | 30V 12A |
Products list | brand | Model No. | Home