CP 300 SERIES POWER METER
Specification
Line measure | Single phase, two conductor (1Ø2W) |
Values measured | Voltage, current, Active power, power factor, reactive power, apparent power, frequency. |
Measurement ranges ¡@ |
Voltage,
current and active power see separate table of ranges and resolution. |
Operating principle | Voltage and current: True RMS Power: Analog multiplier circuit. |
Range selection | Auto or manual (remote via RS-232) |
Sampling rate | 3.3 times/sec. |
Input impedance ¡@ |
Voltage:
approx 1M omh |
Maximum allowable input ¡@ |
Voltage:
650V RMS, |
Maximum common mode voltage | Voltage and current input terminals: 600V rms. |
Crest factor | 3 |
Input method ¡@ |
Voltage:
resistance divider |
Input terminals | large binding posts. |
Effective input range | 5% to 100% of the set range. |
Temperature Coefficient | Less than +/- 0.05% f.s / oC |
Averaging function | Displays computed average (fix 3 measured). |
¡@
Computing Function | |||
Apparent Power | Reactive power | Power factor | |
VA = V*A | VAR = (VA2 -W2)^(1/2) | PF = W (VA) | |
Computing Range : VA , VAR : Voltage and current range | |||
PF : Zero to unity leading or lagging |
|||
Computing Accuracy : VA * VAR +/- 0.05% of rated value | |||
PF : +/- 0.001 |
|||
¡@ | |||
Frequency measurement function | |||
Operating Principle | Reciprocal counting method | ||
Measurement range | 5% to 100% set range(10Hz ~ 100KHz) | ||
Auto Range | 45Hz / 10KHz / 100KHz | ||
Accuracy | +/- 1 DGT of the range | ||
Measurement Cycle | 3.3 times / sec | ||
Display Range | 10.00Hz ~ 99999Hz(5 digits) | ||
¡@ | ¡@ | ||
Interface | |||
RS-232 | Baud Rate¡G1200 , 2400 , 9600 bps. | ||
¡@ | Transmission system : Srart-stop synchronization 8 bits , 1 stop bit. none parity | ||
¡@ | ¡@ | ||
General specification | |||
Dielectric Strength | 2.2KV AC (50/60Hz) for one minute between input terminals and case. | ||
Insulation Resistance | more than 20M£[ at 500V dc between input terminals and case between case and power line. | ||
Operating Temperature | 5 to 50oC (41 to 104oF) | ||
Humidity Range | 10 to 90% (relative humidity) non-condensing. | ||
Line Requirements | AC115V or 230V +/- 15%, 48 to 63 Hz 15VA | ||
Dimensions/Weight | 260x110x360(WxHxD)/4.8Kgs net. | ||
|
¡@
Consult the Factory The Customer Specification. Specifications Subject to Change Without Notice. |
¡@