IT-M3200 High Precision Programmable DC Power Supply
Product Features
Feature
♦ 1U Half-rack, maximum
power is up to 360W
♦ Wide range measurement
♦ Low ripple and noise
♦ High resolution, high
accuracy and high stability
♦ Current readback is up to
10nA
♦ Four current measurement
ranges Low/Middle/High/Auto
♦ CC/CV priority setting
♦ Foldback
♦ Adjustable rise/fall
time, soft start / stop
♦ Independent control of
multiple channels, up to 16 channels
♦ Different timing output
of each channel to achieve synchronization or proportional tracking
♦ List
♦ Support multiple
communication protocol,CANOPEN,LXI,SCPI
♦ Five optional cards,
supporting RS232,CAN,LAN,GPIB, USB_TMC,USB_VCP,RS485, analog and IO
communication
♦ Multiple protection, OVP/OCP/OTP/OPP/UVP/UCP
Functions and Advantages
1U half rack Mini size
IT-M3200 provides 360W
power output with 1U half rack size. Besides of the high-power density, it has
high resolution, high accuracy and multi-range
measurement functions. With auto-ranging design, the device covers a wide range
of application requirements.
Multi-level current range
IT-M3200 high precision
power supply provides multi-level (Low/Middle/High/Auto) current range
switching, with resolution up to 10nA, to meet the current measurement needs
from Amp level to micro-amp level. The user can realize the flexible switching
between low and high current measurement at the Auto level, no need to control
manually. This function is suitable for testing in the fields of 5G, wearable
devices and other low power consumption products.
Foldback
protection
IT-M3200 Series with Foldback protection function, is used for turn off the output when the power supply is switched by CV/CC, to protect certain DUT that are sensitive to voltage overshoot and current overshoot. User can specify working mode and set the delay time protection, if the current working mode is switched, it will trigger the protection and turn off the output when the delay time is used up.
Soft start/ stop function
IT-M3200 Series can be
set the rise up and fall time of output voltage or
current to prevent the sudden up and down of voltage at the moment of onloading
or unloading, triggering the DUT false protection
action.
List Function
Users can modify and edit
the output waveform of the voltage and current with time according to
customer's test requirements without use the software, also can control the
voltage rise and decline slope. the power supply will automatically transform
the output according to pre-edited waveform after receiving the trigger signal.
Link function
The Link function is
mainly designed for the cascade control of multiple devices. It is especially
suitable for the multiple DUT synchronized testing or
the application of multi-channel power input. IT-M3200 series support Duplicate
/ On-Off / Track of three modes, user only need to set the parameters on one of
the power supplies, then automatically copy the set parameters or
proportionally synchronize to other devices of M3200 series in the cascade
circuit. IT-M3200 series may performance two solutions of synchronous power-on
and in sequence power-on When the link-on / off function is used with the on /
off delay function in the menu.
Options & Accessories
·
IT-E154A/B/C (Optional)
Cabinet rack kit
·
IT-E1203 (Optional)
Temperature sensor
·
IT-E118 (Optional)
Anti-reverse connection module...
·
IT-E31220-OO (Optional)
120A/2m/round terminal, a pair...
·
IT-E33620-OO (Optional)
360A/2m/round terminal, a pair...
·
IT-E251 (Optional)
Multi - machine interconnection...
·
IT-E32420-OO (Optional)
240A/2m/round terminal, a pair...
·
AC power cord (accessories)
AC power cord (accessories)
·
IT-E1209 (Optional)
USB communication card
·
IT-E1208 (Optional)
External analog/RS485 communic...