IT6800A/B Single Channel Programmable DC Power Supply
IT6800 single channel programmable DC power supply
(180W-216W) with resolution 1mV/0.1mA, users can adjust the voltage/current
stepping by pressing the left and right keys to moving the cursor and programs
by the front panel. OVP/OTP protection. IT6800
supports timer function and their built-in RS232 and USB communication
interfaces offer you a convenience testing experience.
Model Voltage Current Power Interface |
||||
IT6831A |
18V |
10A |
180W |
USB/RS232 |
IT6832A |
32V |
6A |
192W |
USB/RS232 |
IT6832B |
32V |
6A |
192W |
USB/RS232/GPIB |
IT6833A |
72V |
3A |
216W |
USB/RS232 |
IT6833B |
72V |
3A |
216W |
USB/RS232/GPIB |
IT6835A |
50V |
4A |
200W |
USB/RS232 |
IT6835B |
50V |
4A |
200W |
USB/RS232/GPIB |
*IT6800A single channel series is standard model, IT6800B single channel series is optional if you need GPIB interface.
* The above specifications are subject to change without prior notice.
Product Features
♦ Support
panel programming, numeric keypad operation
♦ High accuracy and resolution 1mV/0.1mA
♦ Outputs according to the programmed voltage and
current values
♦ Adjust the voltage and current via knob
♦ Lower ripple and noise
♦ Remote sense
♦ Built-in RS232 / USB/ GPIB interface *1
♦ Intelligent fan control, save energy and reduce
noise
*1 Built-in GPIB is available with IT6800B series only
Functions and Advantages
Support panel programming
function (List)
The IT6800A Series single channel Programmable DC Power Supply generates a
variety of output change sequences by sequentially operating each single step
value and time. The parameters in the sequence include time units, single-step
voltage, single-step current, single-step time, and the next step
, looping steps, saving files, and so on. After the sequential operation
is completed, when a trigger signal is received, the power is turned on until
the sequence operation is completed or another trigger signal is received
again.
Remote sense function
In order to avoid the pressure drop caused by the length of the wire connecting
the load, the remote test allows measurement directly on the terminal of the
test object to improve the measurement accuracy. S +, S is the remote
measurement terminal, +, - is the output positive and negative terminals. When
using the remote measurement function, it is necessary to disconnect the wires
connected to the "+, -" terminals and lead S +, S to the test object.
Output timer
IT6800A/B series supports Output timer function,users can start this function in the Menu
and set the time. The timers starts working when the
unit is powered on. The unit will automatically turn off the output when the
set time is due. Timing time setting range 0.1 - 9999.9S or 0.1 - 9999.9M.
Options & Accessories
·
CD (accessory)
With user manual and communica...
·
AC power cord (accessory)
AC power cord (accessory)
·
IT-E151A (Optional)
19'' Rack mount kit
·
IT-E151 (Optional)
19'' Rack mount kit
·
IT-E30110-AB (Optional)
10A/1m/Alligator clip - Banana...
·
IT-E30110-BB (Optional)
10A/1m/Banana plug - Banana pl...
·
IT-E30110-BY (Optional)
10A/1m/Banana plug - Y termina...