IT8000 Series Regenerative DC Electronic Load
IT8000 series is a family of high power regenerative electronic loads with compact size. The highly integrated capability enables the e-load to simulate various e-load characteristics, and return the consumed energy back to the grid cleanly, saving costs related to energy consumption and cooling, meanwhile eco-friendly. With modular high-power density design, IT8000 provide up to 18kW in 3U space. The power is expandable up to 1152kW by master-slave paralleling and active current sharing. If you move into application of high-power UPS, storage battery, PV battery, EV, energy storage system, ITECH can help you with IT8000 series high power regenerative electronic load.
Current |
Power |
Model |
Current |
Power |
Model |
Current |
Power |
||||
80V |
IT8005-80-150 |
150A |
5kW |
300V |
IT8006-300-75 |
75A |
6kW |
500V |
IT8006-500-40 |
40A |
6kW |
IT8010-80-300 |
300A |
10kW |
IT8012-300-150 |
150A |
12kW |
IT8012-500-80 |
80A |
12kW |
|||
IT8015-80-450 |
450A |
15kW |
IT8018-300-225 |
225A |
18kW |
IT8018-500-120 |
120A |
18kW |
|||
IT8030-80-900 |
900A |
30kW |
IT8036-300-450 |
450A |
36kW |
IT8036-500-240 |
240A |
36kW |
|||
IT8045-80-1350 |
1350A |
45kW |
IT8054-300-675 |
675A |
54kW |
IT8054-500-360 |
360A |
54kW |
|||
IT8060-80-1800 |
1800A |
60kW |
IT8072-300-900 |
900A |
72kW |
IT8072-500-480 |
480A |
72kW |
|||
IT8075-80-2040 |
2040A |
75kW |
IT8090-300-1125 |
1125A |
90kW |
IT8090-500-600 |
600A |
90kW |
|||
IT8090-80-2040 |
2040A |
90kW |
IT8108-300-1350 |
1350A |
108kW |
IT8108-500-720 |
720A |
108kW |
|||
IT8105-80-2040 |
2040A |
105kW |
IT8126-300-1575 |
1575A |
126kW |
IT8126-500-840 |
840A |
126kW |
|||
IT8120-80-2040 |
2040A |
120kW |
IT8144-300-1800 |
1800A |
144kW |
IT8144-500-960 |
960A |
144kW |
Model Current Power Model Current Power Model Current Power |
||||||
800V |
IT8006-800-25 25A 6kW |
1500V |
IT8018-1500-40 40A 18kW |
2250V |
IT8018-2250-25 25A 18kW |
|
IT8012-800-50 50A 12kW |
||||||
IT8036-1500-80 80A 36kW |
IT8036-2250-50 50A 36kW |
|||||
IT8018-800-75 75A 18kW |
||||||
IT8054-1500-120 120A 54kW |
IT8054-2250-75 75A 54kW |
|||||
IT8036-800-150 150A 36kW |
||||||
IT8072-1500-160 160A 72kW |
IT8072-2250-100 100A 72kW |
|||||
IT8054-800-225 225A 54kW |
||||||
IT8072-800-300 300A 72kW |
IT8090-1500-200 200A 90kW |
IT8090-2250-125 125A 90kW |
||||
IT8090-800-375 375A 90kW |
IT8108-1500-240 240A 108kW |
IT8108-2250-150 150A 108kW |
||||
IT8108-800-450 450A 108kW |
||||||
IT8126-1500-280 280A 126kW |
IT8126-2250-175 175A 126kW |
|||||
IT8126-800-525 525A 126kW |
||||||
IT8144-1500-320 320A 144kW |
IT8144-2250-200 200A 144kW |
|||||
IT8144-800-600 600A 144kW |
* The above specifications are subject to change without prior notice.
Product Features
Features
♦ Recover DC energy
to local grid with efficiency up to 95%
♦ Stand-alone power up to
144kW, expandable by master-slave paralleling up to 1152kW
♦ Stand-alone input voltage
up to 2250V
♦ Stand-alone input current
up to 2040A
♦ High power density design
provides 18kW in 3U space
♦ Built-in waveform
generator, support generating arbitrary waveforms
♦ LIST function,
support importing LIST files by USB
♦ Power accumulation
function
♦ Battery test function,
auto-test function, short circuit test function
♦ With pre-charging
function, prevent DC loading current overshoot
♦ Full protection: OVP/OCP/OPP/OTP/UVP, Vsense anti-reverse
connection protection, and voltage transient drop protection
♦ Built-in standard
USB/CAN/LAN/digital IO interface, and optional
♦ GPIB/Analog&RS232
interfaces
♦ Support SCPI protocol, LabVIEW
♦ Operating mode:CC/CV/CP/CR/CC+CV/CV+CR/CR+CC/CC+CV+CP+CR
*The regenerated power is
for local grid purpose, not for public grid purpose
Application
Functions and Advantages
Power regenerative efficiency up to 95%
High energy regenerative efficiency. The IT8000series has a unique energy regenerative function that can regenerate electrical energy and then directly use it in the plant instead of consuming it in the form of heat. Its conversion efficiency can up to 95%, which not only will greatly reduce the user's electricity cost, but also avoid the use of air conditioning or expensive cooling systems.
High power density
Conventional electronic loads are not only with high energy consumption, but also with very large size and weight. Energy consumption electronic load with 30KW load is at least 24U, it is difficult to transport and the cost is higher. IT8000 series regenerative DC electronic load adopts high power density design of 18kW in only 3U high. Compared to conventional electronic loads, the size for IT8000 series is decreased by 80% under the same output power.
Power accumulation function
IT8000 series regenerative DC electronic load uses the power electronic transformation technology on the premise of completing test power experiment to make output energy of measured power supply regenerative recycled and reused. Through the inside fast sampling of voltage and current, the regenerative power value can be observed on the front panel of IT8000 series, including voltage, frequency and power of each phase, as well as total power, total current regenerative and total historical regenerative power, which makes the energy saving effect much easier. Re-open after power failure, IT8000 series will continue to accumulate the regenerative power value based on the last power off value.
List function
IT8000 series regenerative DC electronic load provides list mode, it can complete the complex arbitrary current change mode accurately and fast, and can synchronize with internal or external signals to complete multi-level loading precision test, which greatly save cost for customers. By editing the step value, pulse width and the slope of each step, IT8000 can generate a variety of complex sequences and help users to complete various loading waveforms test. In the CC mode, IT8000 series can set rising and falling speed.
Battery test function
IT8000 series regenerative DC electronic load simulate battery discharge test under CC mode, and support settable discharge cut-off conditions, such as cut-off voltage, cut-off capacity and cut-off time. When any of the three conditions are met, the discharge test will be stopped. Moreover, the battery voltage, discharge time and the discharged capacity can be observed during the test, which reflects the reliability of the battery and its remaining life.
Patented parallel technology
Advantage:
♦ IT8000 has adopted ITECH parallel technology
♦ All the function and performance will be the same as standalone unit
♦ No need to calibrate after paralleling
♦ Fiber transmission, good for anti-interference
♦ Digital paralleling, fully insulated, good for protecting DUT
Full protection
IT8000 series regenerative DC electronic load supports automatic detection the grid state . When grid connection is suddenly disconnected or power down, IT8000 will be turned off. IT8000 series can achieve reliable on-grid function and anti-islanding protection function. IT8000 supports monitoring on DC input voltage and frequency, and supports OCP, OVP, OTP, OPP function.
Options & Accessories
·
AC power cord (accessory)
AC power cord (accessory)
·
USB
For USB port communication
·
CD (accessory)
With user manual and communica...
·
IT-E167 (Optional)
RS232 / analog communication c...
·
IT-E166 (Optional)
GPIB communication card
·
IT-E33620-OO (Optional)
360A/2m/ round terminal, a pai...
·
IT-E32420-OO (Optional)
240A/2m/ round terminal, a pai...
·
IT-E32410-OO (Optional)
240A/1m/ round terminal, a pai...
·
IT-E31220-OO (Optional)
120A/2m/ round terminal, a pai...
·
IT-E30615-OO (Optional)
60A/1.5m/ round terminal, a pa...
·
IT-E30320-YY (Optional)
30A/2m/Y terminal, a pair of r...
·
IT-E30312-YY (Optional)
30A/1.2m/Y terminal, a pair of...