3310D series Module are used with the 3302C single mainframe and 3300C 4ch Mainframes. |
Each 3310D Series Module has its own control and display panel, CC/CR/CV/CP/Dynamic modes, 150 Store/Recall memory which provides load set-up more efficiently. |
SHORT time setting and SHORT_VH, SHORT_VL setting function |
Dynamic can be simulated under CC, CP mode. The current Rise/Fall slew rate can be adjusted individually and there is and external signal input so that load can have a simulated Arbitrary Waveform. |
OCP, OPP test function operated by both mainframe and module that will be more effective and accuracy on OCP, OPP testing. |
Programmable Load ON/OFF voltage, GO/NG meter check, Voltage meter display "+" or "-" is selectable and 150 sets larger memory is much advance features than 3310C series.
|
|
MODEL |
3310D |
3311D |
3312D |
3314D |
3315D |
MAX POWER |
150W |
300W |
300W |
300W |
75W |
MAX CURRENT |
30A |
60A |
10A |
10A |
15A |
OPERATOR VOLTAGE |
60V |
60V |
250V |
500V |
60V |
OVER POWER PROTECTION |
--- 157.5W |
¡Ü 315W |
¡Ü 315W |
¡Ü 315W |
--- 78.75W |
OVER CURRENT PROTECTION |
--- 31.5A |
¡Ü 63A |
¡Ü 10.5A |
¡Ü 10.5A |
¡Ü 15.75A |
OVER VOLTAGE PROTECTION |
--- 63A |
¡Ü 63V |
¡Ü 262.5V |
¡Ü 525V |
¡Ü 63V |
OVER TEMP. PROTECTION |
-85¢J |
CC MODE |
RANGE |
0 - 3A |
0 - 30A |
0 - 6A |
0 - 60A |
0 - 1A |
0 - 10A |
0 - 1A |
0 - 10A |
0 - 1.5A |
0 - 15A |
RESOLUTION |
0.8mA |
0.8mA |
1.6mA |
1.6mA |
0.268mA |
0.268mA |
0.268mA |
0.268mA |
0.4mA |
0.4mA |
ACCURACY |
¡Ó 0.2% OF(SETTING + RANGE) |
CR MODE |
RANGE |
2-7.5K£[ |
0.1067-2£[ |
1-3.75K£[ |
0.0533-1£[ |
25-18.75K£[ |
1.333-25£[ |
50-18.75K£[ |
2.666-50£[ |
4-15K£[ |
0.213-4£[ |
RESOLUTION |
0.133mS |
0.533m£[ |
0.266mS |
0.266m |
0.053mS |
6.666m£[ |
0.005mS |
13.33m£[ |
66.66uS |
1.066m£[ |
ACCURACY |
¡Ó 0.2% OF(SETTING + RANGE) |
CV MODE |
RANGE |
0 - 60A |
0 - 60A |
0 - 250A |
0 - 500A |
0 - 60A |
RESOLUTION |
0.016V |
0.016V |
0.0667V |
0.133V |
0.015V |
ACCURACY |
¡Ó 0.1% OF(SETTING + RANGE) |
CP MODE |
RANGE |
0 - 150W |
0 - 300W |
0 - 300W |
0 - 300W |
0 - 75W |
RESOLUTION |
0.04W |
0.08W |
0.08W |
0.08W |
0.02W |
ACCURACY |
¡Ó 0.5 OF(SETTING + RANGE) |
DYNAMIC OPERATION |
THIGH & TLOW |
50uSec TO 9.999Sec |
SLEW RATE |
2.0-125 mA/uSec |
20mA-1.2 5A/uSec |
4-250 mA/uSec |
40mA-2.5A/uSec |
0.8-50 mA/uSec |
8mA-50A/uSec |
0.8-50 mA/uSec |
8mA-500A/uSec |
1.0-62.5 mA/uSec |
10mA-0.625A/uSec |
ACCURACY |
¡Ó (10% OF SETTING) ¡Ó10uS ¡Ó(10% OF SETTING) ¡Ó10uS |
VOLTAGE READBACK(AMETER) |
RANGE |
15.0V |
60.0V |
15.0V |
60.0V |
30.0V |
250.0V |
=199.99V |
=500.0V |
15.0V |
60.0V |
RESOLUTION |
0.001V |
0.002V |
0.001V |
0.002V |
0.001V |
0.01V |
0.01V |
0.1V |
0.001V |
0.02V |
ACCURACY |
=0.05% OF(SETTING + RANGE) |
CURRENT READBACK(AMETER) |
RANGE |
3.0A |
30.0A |
6.0A |
60A |
1.2A |
12.0A |
=10.00A |
1.5A |
15.0A |
RESOLUTION |
0.001A |
0.01A |
0.001A |
0.01A |
0.0001A |
0.001A |
1mA |
0.0001A |
0.001A |
ACCURACY |
¡Ó 0.2% OF(SETTING + RANGE) |
CURRENT MONITOR OUTPUT |
FULL SCALE 10V (ISOLATED WITH LOAD MODULE) |
CURRENT PROGRAME INPUT |
FULL SCALE 10V (ISOLATED WITH OTHER LOAD MODULE) |
PROGRAMMABLE SHORT |
BUILT - IN |
LOAD ON VOLTAGE |
0.1-25V |
0.1-25V |
0.2-50V |
0.4-100V |
0.1-25V |
LOAD OFF VOLTAGE |
0-25V |
0-25V |
0-50V |
0-100V |
0-25V |
MAX. SHORT RESISTANCE |
0.0115£[ |
0.0057£[ |
0.0625£[ |
0.43£[ |
0.017£[ |
MAX. SHORT CURRENT |
30A |
60A |
10A |
10A |
15A |
|
|
|
|
|
|
|
|
|
|
|
|