3600A Automatic RS-232C, Centronics
Test items | Features |
Hold-On Adjust . |
All in one, Stand Alone SMPS tester, 3600A series includes 800VA AC source,
Four DC Load with Flexi able Polarity configuration, One OVP, Two Timing
and |
Load Regulation . | |
Line Regulation . | Manual or Computer Edit Mode . |
Combine Regulation . | Manual, Auto, or Step Testing Mode . |
Efficiency . | Centronics for all data direct print output or store on file. |
Power Good / Fail . | RS-232C for Download/UpLoad Testing Procedure . |
Set-up / Hold-up time . | Electronic Calibration . |
P-P Noise (PARD) . | Ready to use Testing Fixture . |
OVP Testing . |
Re-installable Option for PARD, Line Regulation, AC Meter, or change to DC Meter. |
OCP Testing . | ¡@ |
Short Testing . | ¡@ |
Applications |
Up to four output Power supply with any configuration of 2+/2-, 3+/1-, or 4+ |
Single, Qual, Tripple, or Quad Total output power up to 630W power supply . |
AC / DC Power Supply . |
DC / DC Converter . |
Production Line . |
Quality Control . |
Incoming Inspection . |
Engineering Evaluation . |
¡@
Descriptions
The 3600A series was designed for testing AC /
DC and DC / DC power supply up to 630W, it will accommodate power
supplies with as many as four outputs. It will store test programs for
eight different power supply specifications. Each of these tests may
include up to 32 steps of sub testing. Testing procedures can be
generated and edited manually via front panel or remotely using
Application |
¡@
Electronic load |
||||
Load Channel | 1 | 2 | 3 | 4 |
Input Rating | ||||
Power | 300 W | 250 W |
40 W |
|
Current | 0 - 60 A | 0 - 40 A | 0 - 8A | 0 - 4A |
Voltage | +35V | +50V | ¡Ó50V | ¡Ó50V |
Constant Current (CC) Mode | 0 - 60 A | 0 - 40 A | 0 - 8 A | 0 - 4 A |
Accuracy |
¡Ó 0.5% of ( Reading + Range ) |
|||
Constant Resistance (CR) Mode | 0.083-333£[ | 0.125-500£[ | 0.625-2500£[ | 1.25-5000£[ |
Accuracy | ¡Ó 0.8% of ( Reading + Range ) | |||
Voltage Meter (DVM) | 0.00 - 35.00V | 0.00 - 50.00V | ||
Accuracy | ¡Ó 0.1% of ( Reading + Range ) | |||
Current Meter (DAM) | 0.00 - 60.00 A | 0.00 - 40.00 A | 0.000 - 8.000 A | 0.000 - 4.000 A |
Accuracy | ¡Ó 0.5% of ( Reading + Range ) | |||
PARD @ B.W. 0.2, 2, 20 Mz | Range: 0.000 - 0.750 mV p-p ( -375mV to +375mV ) | |||
Accuracy | ¡Ó ( 2% of Reading + 10mV ) | |||
OVP Voltage | 0.00 - 50.00V |
N / A |
||
Accuracy | 0.2% of (Reading + Range ) | |||
OTHERS: | ||||
Short Testing | 0.04£[ | 0.4£[ | ||
Protection | OVP, OCP, OPP, OTP, | |||
Analog Programming | CH1, HC2 : 0 to +10V, CH3, CH4 : 0 to ¡Ó10V |
¡@
¡@
|
|
¡@
¡@
General | Accessories |
AC Power: 115/230Vac, ¡Ó10%, 50/60Hz . | Power Cord . |
AC Source Input: 115/230Vac . | 9910 Universal Fixture . |
Weight : 22Kg . | 9920 PC Fixture(PS/2) |
Dimension: 483(W) x 177(H) x 445(D) . | 9800A Application Software . |
Digital Output Port: 8 Bit. | Operation Manual . |
Options | |
3600A001 Delete PARD . | |
3600A002 Delete Line Reg. | |
3600A003 Delete Line Reg., AC Meter . | |
3600A004 Delete PARD, Line Reg., AC Meter . | |
3602A 3600A'S AC source is changed to DC source as a DC & DC test system. | |
3602A001 Delete PARD from 3602A. | |
5030 5A/30V OVP Source . | |
9500 1KVA 115V 50/60Hz input 115V/230V 50/60Hz output AC source . | |
9501 1KVA 230V 50/60Hz input 115V/230V 50/60Hz output AC source . | |
9900 Twin Testing Fixture . | |
9910 Universal Testing Fixture . | |
9920 PC Power Supply(PS/2) Fixture . | |
9921 ATX fixture with (+5,+12,+3.3,+5VSB ). | |
9922 ATX fixture with (+5,+12,+3.3,-12V ). | |
9930 Remote Controller. |