Contact
3602A Series Automatic Power Supply Tester RS-232, Centronics

-
All in one, Stand Alone SMPS tester, 3602A includes DC source Controller, Four
-
DC Load with Flexible Polarity configuration, One OVP, Two Timing and Four
-
PARD Measurement.
-
Manual or Computer Edit Mode
-
Manual, Auto, or Step Testing Mode
-
Centronics for all data direct print output
-
RS-232C for DownLoad/UpLoad Testing Procedure
-
Electronic Calibration
-
Ready to use Testing Fixture
-
Re-installable Option for PARD.
Electronic load |
| Load Channel |
1 |
2 |
3 |
4 |
| Input Rating |
| Power |
300 W |
250 W |
40 W |
| Current |
0 - 60 A |
0 - 40 A |
0 - 8A |
0 - 4A |
| Voltage |
+35V |
+50V |
¡Ó50V |
¡Ó50V |
| Constant Current (CC) Mode |
0 - 60 A |
0 - 40 A |
0 - 8 A |
0 - 4 A |
| Accuracy |
¡Ó 0.5% of ( Reading + Range ) |
| Constant Resistance (CR) Mode |
0.083-333£[ |
0.125-500£[ |
0.625-2500£[ |
1.25-5000£[ |
| Accuracy |
¡Ó 0.8% of ( Reading + Range ) |
| Voltage Meter (DVM) |
0.00 - 35.00V |
0.00 - 50.00V |
| Accuracy |
¡Ó 0.1% of ( Reading + Range ) |
| Current Meter (DAM) |
0.00 - 60.00 A |
0.00 - 40.00 A |
0.000 - 8.000 A |
0.000 - 4.000 A |
| Accuracy |
¡Ó 0.5% of ( Reading + Range ) |
| PARD @ B.W. 0.2, 2, 20 Mz |
Range: 0.000 - 0.750 mV p-p ( -375mV to +375mV ) |
| Accuracy |
¡Ó ( 2% of Reading + 10mV ) |
| OVP Voltage |
0.00 - 50.00V |
N / A |
| Accuracy |
0.2% of (Reading + Range ) |
| OTHERS: |
| Short Testing |
0.04£[ |
0.4£[ |
| Protection |
OVP, OCP, OPP, OTP, |
| Analog Programming |
CH1, HC2 : 0 to +10V, CH3, CH4 : 0 to ¡Ó10V |
|
|