3660A Stand-Alone Automatic Multiple Output Power Supply Tester
 
 

Contact

3660A Stand-Alone Automatic Multiple Output Power Supply Tester

  • The 3660A is an all-in-one stand-alone unit with built-in hardware and software for all testing requirements.
  • Up to 24 test programs can be edited on a PC with Prodigit's 9906A Application Software (WindowsTM version) and downloaded to and stored in the 3660A built-in EEROM for quick access. Power supply (U.U.T.) information including part number, test requirements and results is shown on the large
  • LCD display. This information can be printed out directly or stored in a PC. Test information can be converted to ExcelTM to meet your format requirements.
  • Testing can be done either automatically or in a step-by-step mode. Automatic testing is typically used for high throughput testing applications. Step-by-step testing is used for checking test settings or U.U.T. functions.
  • The optional 9906 Integrated Twin Test Fixture (with built-in OVP Source) is designed for high volume production testing.
  • User friendly 9906A software is compatible with Windows TM and ExcelTM.

Load

1

2

3

4

5

6

Input Rating Power

Current

Voltage

300W

180W

20W

40W

120W

20W

0- 60A

0- 20A

0- 4A

0- 4A

0- 40A

0- 4A

0~ +30V

0~ -30V

0~ +10V

0~ +30V

CC Mode

Accuracy

0- 60A

0- 20A

0- 4A

0- 4A

0- 40A

0- 4A

¡Ó0.5% of ( Setting + Range )

CR Mode

Accuracy

0.05- 200£[

0.15-  600£[

0.75- 3000£[

0.075- 300£[

0.75- 3000£[

¡Ó0.8% of ( Setting + Range )

DVM

Accuracy

0~ +30V

0~ -30V

0~ +10V

0~ +30V

¡Ó0.05% of ( Reading + Range )

DAM

Accuracy

0.00- 60.00A

0.00- 30.00A

0.000- 6.000A

0.00- 60.00A

0.000- 6.000A

¡Ó0.5% of ( Reading + Range )

PARD @ 0.2 , 20MHz

Accuracy

0.000-0.500Vp-p Res. 1mV

¡Ó ( 2% of Reading + 5mV )

OVP Voltage    

Accuracy

0~24V@4A

¡Ó0.2% of ( Reading + Range )

Over  Current Test

80A @ 1 Min

30A @ 1 Min

6A @ 1 Min

80A @ 1 Min

6A@1Min

Short Circuit Test

Electronic/Relay

0.055£[ / 0£[

0.08£[ / 0£[

0.4£[ / 0£[

0.02£[ / 0£[

0.4£[ / 0£[

Remark: For ATX, Power Supply, Load 1: for +5V, Load 2: for +12V, Load 3 : for ¡V5V, Load 4 : for ¡V12V, Load 5 : for +3.3V, Load 6 : for +5Vsb

Isolated AC Source (Build-in ultra fast current breaker)
Output Voltage 800VA, 50/60Hz
115V @7Arms 90, 115, 132 V
230V@3.5Arms 90, 115, 132, 180, 230, 264V
AC Voltage Meter 0.0 - 300.0 Vrms
Accuracy +- 0.3¢M of (Reading + Range)
AC Current Meter 0.00 - 8.00 Arms
Accuracy +- 0.5¢M of (Reading + Range)
AC Power Meter 0.00 - 800.00 W
Accuracy +- 0.5¢M of (Reading + Range)
Timing measurement and control
Power Good / Fail Time
0-9999 mS
Set-up / Hold-up Time
0-9999 mS
Accuracy
¡Ó1 mS
Threshold Voltage
Vth
VPGS
Input Range
0 - 30V
0 - 5.6V
Setting Range
Auto / Step Testing Time
0-30.00V
0-5.60V
Tmeas.1 - Tmeas.32
500.0 mS - 20 Sec
Tdelay.1 - delay.32
0.0 mS - 60 Sec

 

 
 
Products list | brand | Model No. | Home