Contact
3660A Stand-Alone Automatic Multiple Output Power Supply Tester
-
The 3660A is an all-in-one stand-alone unit with built-in hardware and software for all testing requirements.
-
Up to 24 test programs can be edited on a PC with Prodigit's 9906A Application Software (WindowsTM version) and downloaded to and stored in the 3660A built-in EEROM for quick access. Power supply (U.U.T.) information including part number, test requirements and results is shown on the large
-
LCD display. This information can be printed out directly or stored in a PC. Test information can be converted to ExcelTM to meet your format requirements.
-
Testing can be done either automatically or in a step-by-step mode. Automatic testing is typically used for high throughput testing applications. Step-by-step testing is used for checking test settings or U.U.T. functions.
-
The optional 9906 Integrated Twin Test Fixture (with built-in OVP Source) is designed for high volume production testing.
-
User friendly 9906A software is compatible with Windows TM and ExcelTM.
Load |
1 |
2 |
3 |
4 |
5 |
6 |
Input Rating Power
Current
Voltage |
300W |
180W |
20W |
40W |
120W |
20W |
0- 60A |
0- 20A |
0- 4A |
0- 4A |
0- 40A |
0- 4A |
0~ +30V |
0~ -30V |
0~ +10V |
0~ +30V |
CC Mode
Accuracy |
0- 60A |
0- 20A |
0- 4A |
0- 4A |
0- 40A |
0- 4A |
¡Ó0.5% of ( Setting + Range ) |
CR Mode
Accuracy |
0.05- 200£[ |
0.15- 600£[ |
0.75- 3000£[ |
0.075- 300£[ |
0.75- 3000£[ |
¡Ó0.8% of ( Setting + Range ) |
DVM
Accuracy |
0~ +30V |
0~ -30V |
0~ +10V |
0~ +30V |
¡Ó0.05% of ( Reading + Range ) |
DAM
Accuracy |
0.00- 60.00A |
0.00- 30.00A |
0.000- 6.000A |
0.00- 60.00A |
0.000- 6.000A |
¡Ó0.5% of ( Reading + Range ) |
PARD @ 0.2 , 20MHz
Accuracy |
0.000-0.500Vp-p Res. 1mV |
¡Ó ( 2% of Reading + 5mV ) |
OVP Voltage
Accuracy |
0~24V@4A |
¡Ó0.2% of ( Reading + Range ) |
Over Current Test |
80A @ 1 Min |
30A @ 1 Min |
6A @ 1 Min |
80A @ 1 Min |
6A@1Min |
Short Circuit Test |
Electronic/Relay |
0.055£[ / 0£[ |
0.08£[ / 0£[ |
0.4£[ / 0£[ |
0.02£[ / 0£[ |
0.4£[ / 0£[ |
Remark: For ATX, Power Supply, Load 1: for +5V, Load 2: for +12V, Load 3 : for ¡V5V, Load 4 : for ¡V12V, Load 5 : for +3.3V, Load 6 : for +5Vsb |
Isolated AC Source (Build-in ultra fast current breaker) |
Output Voltage |
800VA, 50/60Hz |
115V @7Arms |
90, 115, 132 V |
230V@3.5Arms |
90, 115, 132, 180, 230, 264V |
AC Voltage Meter |
0.0 - 300.0 Vrms |
Accuracy |
+- 0.3¢M of (Reading + Range) |
AC Current Meter |
0.00 - 8.00 Arms |
Accuracy |
+- 0.5¢M of (Reading + Range) |
AC Power Meter |
0.00 - 800.00 W |
Accuracy |
+- 0.5¢M of (Reading + Range) |
Timing measurement and control |
Power Good / Fail Time |
0-9999 mS |
Set-up / Hold-up Time |
0-9999 mS |
Accuracy |
¡Ó1 mS |
Threshold Voltage |
Vth |
VPGS |
Input Range |
0 - 30V |
0 - 5.6V |
Setting Range
Auto / Step Testing Time |
0-30.00V |
0-5.60V |
Tmeas.1 - Tmeas.32 |
500.0 mS - 20 Sec |
Tdelay.1 - delay.32 |
0.0 mS - 60 Sec |
|
|