1201 Power Meter

 

 

 

FEATURES

Dual Digital Display Voltage, Ampere, Watt

Ture RMS Current

Range Auto/Manual Selectable

Power Factor Zero to Unity

Watt Accuracy ±0.3% + 3d

SPECIFICATION

  TRUE POWER

Range

19.99W, 199.9W, 1999W

Accuracy

±(0.3% + 3d)

Freq. Response

40Hz~80Hz

Max. Voltage

299.9V

Max. Current

200mA for 19.99W
2A for 199.9W
20A for 1999W

Power Factor (COSφ)

Zero to Unity Leading or Lagging

Shunt Resistance

0.01 Ω (Current Sense )


  AC VOLTAGE

Auto Range

0~299.9V

Accuracy

±(0.25% +2d)

Freq. Response

40Hz~1kHz

Protection

300V

Impedance

Above 200K Ω


  AC CURRENT

Range

.1999A, 1.999A, 19.99A

Accuracy

±(0.3% +2d)

Freq. Response

40Hz~200Hz for 1999A
40Hz~1KHz for 1.999~19.99A

Peak over Indication

2.5 times of Range

Shunt Resistance

0.01 Ω

Crest Factor Response

50:1 for Minimum RMS Input,
Linearly decreasing to 3:1 for Full Scale RMS Input


  GENERAL

Displays

DUAL 4 Digits 7-Segment L.E.D.

WATTS/AMPERE Reading

3 Auto Range up at 2000 Counts
                       down at 0.180 Counts

Min. Input

10% of Range for All True RMS Converters

Dimension

260(W)x100(H)X340(D) mm

Weight

4Kgs

Power

115V/230V ±10%, 50/60Hz, 10w

Specifications subject to change without notice.

 

 

Products list | brand | Model No. | Home