Model |
DS5202CA |
DS5152CA/5152MA |
DS5102CA/5102MA |
DS5062CA/5062MA |
|
Bandwidth |
200 MHz |
150 MHz |
100 MHz |
60 MHz |
|
Real-time Sample Rate |
1 GSa/s |
Equivalent Sample Rate |
50 GSa/s |
Memory Depth |
4K points per channel |
refresh rate |
1000wfms/s |
Model |
DS5152C/5152M |
DS5102C/5102M |
DS5062C/5062M |
DS5042M |
DS5022M |
Bandwidth |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
25 MHz |
Real-time Sample Rate |
500 MSa/s |
Equivalent Sample Rate |
50 GSa/s |
Memory Depth |
4K points per channel |
refresh rate |
1000wfms/s |
In the product model¡Amark C means color LCD¡Amark M means mono LCD.
Advanced Features
1. Real-time sample rate is up to 1 GSa/s and equivalent sample rate is up to 50 GSa/s |
2. Capture rate is up to 1K/s |
3. Dual channels and bandwidth from 25 MHz to 200 MHz |
4. Digital filter and waveform recorder |
5. Color LCD display or mono LCD display |
6. 20 automatic measurements |
7. Cursor measurements: Manual, Track and Auto Measure modes |
8. 10 waveforms, 10 setups: Storage and Play-back |
9. Add, Subtract, Multiply and Divide math functions |
10. Powerful triggers: Edge, Video, Pulse width, Delay |
11. Built-in FFT spectrum analyzer function |
12. Automatic self cabiration |
13. Built-in hardware frequency counters |
14. Standard interface: USB Device |
15. Optional extension module: Pass/Fail test module, RS-232/GPIB communication module |
16. Multiple-language user interface |
|
Model |
DS5202CA |
DS5152CA/5152MA |
DS5102CA/5102MA |
DS5062CA/5062MA |
Bandwidth |
200 MHz |
150 MHz |
100 MHz |
60 MHz |
Real-time Sample Rate |
1 GSa/s |
Equivalent Sample Rate |
50 GSa/s |
Rise Time |
1.8 ns |
2.3 ns |
3.5 ns |
5.8 ns |
Input Impedance |
1 M£[ || 13 pF (50 £[) |
1M£[ || 13 pF |
Time Base Range |
1 ns/div to 50 s/div |
2 ns/div to 50 s/div |
5 ns/div to 50 s/div |
X-Y Operation |
Bandwidth |
200 MHz |
150 MHz |
100 MHz |
60 MHz |
Phase Difference |
¡Ó 3¢X |
Display |
Color LCD/Mono LCD |
Model |
DS5152C/5152M |
DS5102C/5102M |
DS5062C/5062M |
DS5042M |
DS5022M |
Bandwidth |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
25 MHz |
Real-Time Sample Rate |
500 MSa/s |
Equivalent Sample Rate |
50 GSa/s |
Rise Time |
2.3 ns |
3.5 ns |
5.8 ns |
8.8 ns |
14 ns |
Input Impedance |
1 M£[ || 13 pF¡A50 £[ |
1M£[ || 13 pF |
Time Base Range |
1 ns/div to 50 s/div |
2 ns/div to 50 s/div |
5 ns/div to 50 s/div |
10 ns/div to 50 s/div |
20 ns/div to 50 s/div |
X-Y Operation |
Bandwidth |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
25 MHz |
Phase Difference |
¡Ó 3¢X |
Display |
Color LCD/Mono LCD |
Mono LCD |
Common Parameters |
Channels |
Dual Channels + External Trigger |
Memory Depth |
4K points per channel |
Vertical Sensitivity |
2 mV/div to 5 V/div |
Vertical Resolution |
8 bits |
Input Coupling A1 & A2 |
DC, AC, Ground |
Trigger Modes |
Edge, Video, Pulse Width, Delay |
Trigger Sweep Modes |
Auto, Normal, Single |
Trigger |
CH1¡BCH2¡BExt¡BExt/5¡BAC line |
Horizontal Time Accuracy |
¡Ó 0.01% |
Maximum Input Voltage |
400 V(DC + AC peak¡B1 M£[ Input Impedance¡B10X), 5 V (Vrms, 50 £[ Input Impedance, BNC) |
Math |
Add, Subtract, Multiply, Divide, Reverse |
Automatic Measurements |
Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle, Delay 1¡÷2, Delay 1¡÷2 |
Cursor Measurements |
Manual, Track and Auto Measure modes |
Storage |
10 Waveforms and Setups |
FFT |
Window modes |
Hanning¡AHamming¡ABlackman-Harris¡ARectangular |
Sample Size |
1024 points |
Power |
Worldwide Use, 100 - 240 V / 40 VA Max |
Weight |
4.5 kg |
|