Type 1600H     Headphone Measuring System

 

Main Functions

The following items of earphone and headphone can be measured:

(1) Frequency response

(2) Sound pressure sensitivity at 1 kHz (1 kHz can be changed)

(3) Average sensitivity of sound pressure within a frequency range

(4) Polarity

(5) DC  Resistance (DCR)

(6) AC Impedance (ACZ)

(7) Distortion at 6 points

(8) Fo

(9) Qe

(10) Qt

(11) Qm

(12) Automatic PASS/FAIL judgment of above items (1) to (7)

(13) Curve of distortion against frequency

(14) Curve of distortion against SPL

(15) Curve of AC impedance.


| Catalogue | Example of  Testing Screen |


 

The fundamental combination of Type 1600 H 

Item

Model No.

Description Usage

1.

160 A

Electro acoustic Analyzer

Mainframe. To control  and process the inputoutput signal.

2.

Monitor & Keyboard

High Resolution Color Display Monitor & Keyboard

Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax.

3.

171

Electro acoustic Testing Adapter

Combines with 160 mainframe, to test the freq. response curvesensitivityimpedanceFopolaritydistortionparameter etc. of the loudspeakerheadphone speaker box.

4.

142 EH

Artificial Ear ( 142 EH = IEC - 318 ) 

Receives the sound generated from the headphone. 142EH is more suitable than Model-142EA-S for testing the headphone, since its frequency range is wider.

5.

X-Y Mouse

Mouse

Replace the upward, downward, leftward, rightward and enter keys on the keyboard.

6.

HP Printer

( Option )

Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.)

Print out the tested results & data.

 

Functions and Specifications of   Type 1600 H

(1)   Frequency response curve : Sweep range can be set from any two frequencies between 20 Hz to 20 kHz. The

interval of sampling frequency points can be set from 1/12, 1/24 or 1/48 octave (1/12 Oct. means 12 points in one

octave). Two response curves can be stored (two colors) for comparison purpose. The dB value of each curve at

any frequency, or the difference between two curves can be read out directly.

 

Dynamic range of frequency response : 70 dB in two ranges: 50 to 120 dB SPL and 70 to 140 dB SPL.

 

Test voltage for response measurements can be set freely : 0.005V to 5.000V.   Accuracy : +/- (0.8%+0.0003V), Resolution: 0.001V.  

 

Set of the upper and lower limits of the frequency response : Use 1 to 5 earphones to draw 5 reference curves on screen. This system will expand +/- X dB automatically according to the outline of the curves to form the upper and lower limit curves. The value X can be set by the user. After that, any point at each curve can be modified freely to fit the real requirement. When frequency response is measured, the measured curve is compared with the limits to determine PASS or FAIL automatically, and a beep means fail.

 

Tolerance in frequency response and sensitivity test :

(A)    Main unit 171: +/- 0.1 dB (50 Hz to 20 kHz);  +0.1/-0.3 dB (20 Hz to 30 kHz).

(B)    142EH measuring microphone in artificial ear: -46.0 dB V/μbar +/- 0.5 dB @ 1 kHz; Frequency response

+/- 1 dB (30 Hz to 7 kHz) , +/- 1.5 dB (20 Hz to 20 kHz).

 

 

(2), (3) Sound pressure sensitivity : After the sweep, the 1kHz Sound pressure sensitivity is displayed automatically.

The average value of dB SPL (average sound pressure sensitivity) is than calculated automatically within the

frequency range f1 to f2 and displayed. Values of f1  and f2 can be set freely in the range of 20 Hz to 20 kHz. The

upper and lower limits for these two sensitivities can be set respectively and the automatic PASS/FAIL judgment

will be performed and displayed.

 

(4)  Polarity : 1600H can measure the polarity of earphone and headphone directly.

 

(5), (6) and (15) DCR, ACZ and Impedance curve :

DCR : Test range from 0.00Ωto 1000Ω,  Accuracy : +/- (1% of rdg. + 0.05Ω),  Resolution: 0.01Ω.

ACZ : Test range from 0.00Ω to 4000Ω,  Accuracy :  +/- (1% of rdg. + 0.05Ω), for ACZ<1 kΩ

+/- 2% of rdg. for ACZ = 1kΩ to 4kΩ ; Resolution: 0.01Ω.

 

Impedance curve : Impedance curve can be drawn out in any band within the range of 20 Hz to 30 kHz.

 

 

(7), (13) and (14) Distortion measurement : There are three modes:

(A)    Distortion measurement at six frequency points: Six fundamental frequencies can be set

  freely within the range 20 Hz to 10 kHz. The fundamental frequency points can be chosen from

 1 to 6, and the less the faster. Test voltage can be set from 0.02 V to 5 V. The upper limit of

 distortion can be set from 0.2% to 20%. Automatic PASS/FAIL judgment will be performed.

(B)    Distortion curve measurement : Distortion curve can be automatically measured within the

 range fL to fH, in step 1/12, 1/24 or 1/48 Oct. Test voltage can be set from 0.02 V to 5 V.

(C)    Curve of distortion against SPL : Each of three frequencies chosen in the range from 20 Hz

to 10 kHz is fed to earphone or headphone under test. The feeding voltage increases from small

to large gradually. The SPL and its distortion are then measured and the results are shown as

three curves in red, yellow and green. The SPL range is from 100 dB to 140 dB.

 

For the above three distortion measurement, the test range is from 0.1% to 20%. One of the following harmonic distortion can be selected: 2nd, 3rd, 4th, 5th, 6th, 7th, 2nd and 3rd, 2nd to 4th, 2nd to 5th, and THD.

 

(8) to (11) Fo, Qe, Qt and Qm : Automatic search of Fo, and displayed digitally. Test range from 13 Hz to 3 kHz with tolerance of +/- 1% , Resolution : 0.1 Hz.