Type 1900   Features and Functions

 

PC Microcomputer Based.                                                                                                               

Uses the AIR TO AIRtesting mode ( Should be combined for use with HP8922 or R&S CMD55 ) instead of the DAI TO DAItesting mode , using the AIR TO AIR testing mode means that the mobile phone and the instrument are communicated in RF form, to simulate the actual communicating situation,  thereby to ensure that the  complete acoustic performance testing of the mobile phone is actually being done on site. While using the DAI TO DAI testing mode, only partial range of testing is being done and therefore no one knows how  well the acoustic performance is.

Highly automation : Model-190A mainframe can fully control the open/close of the  cover of Model-191 Test Fixture, to attain the purpose  for automation of  the Close cover testingopen cover, aside from auto control function, manual control for the open/close of the cover also allowable, very suitable for 100%QC in the production line.

Testing items include : Frequency response curve, distortion, loudness rating  of the receiving, sending and  sidetone.

Sensitivity upper/lower limits and frequency response upper/lower limits can all be set by the user, after completed the testing , auto judging the PASS/FAIL.

Curves are displayed in various colors : Can display simultaneously the upper/lower limits and the frequency response curve of the mobile phone measured.

Has the curve memory function : This function is suitable for making curves comparison. Example: To modify the circuit, stored first the curve prior to modification , after the modification, repeat the testing, two curves appear on the screen, which are the curves prior to and after the  modification , user can make improvement based on these two curves; the dB values at all the frequency points of the curves and the difference of the  dB value at the same frequency between two curves can all be read out simultaneously .

Simple operating commands, user can operate the instrument easily even without referring to the user manual.

Can be linked with the HP printer, to print out the data and curve.

In process of testing,  guiding message will appear on the screen if necessary, to ensure the correct using by the user.    

Model-190A is built-in with a tracking filter , to reduce the influence of the ambient noise, when used in a noisy production line, the test accuracy is not influenced.

Model-191 Test Fixture contains the sound absorption material, which can reduce greatly the ambient noise.

Model-190A can perform sequential testing : All the required  testing  items can be tested sequentially at one time, after completed the testing, a “Test Report” will appear on the screen, and will display a big “PASS” in green or a big “FAIL” in red which  indicate clearly the qualified or disqualified items respectively, this function is suitable in production line use.

Has the auto statistics function  : All the testing items can automatically statistic the qualified items of quantity (Percentage included), the disqualified items of quantity (Percentage included), average of the loudness rating value and the total test quantity, total qualified quantity (and its percentage), total disqualified quantity (and its percentage) etc.