Model |
APF-33006 |
APF-33010 |
APF-33015 |
APF-33020 |
APF-33030 |
APF-33045 |
APF-33060 |
APF-33075 |
Capacity
(kVA) |
6 |
10 |
15 |
20 |
30 |
45 |
60 |
75 |
Circuit
Type |
IGBT/PWM type
|
Input |
Phase |
Three
phase |
Wave |
Sine
wave |
Voltage |
220V/380V |
Voltage
range |
220V/380V±15% |
Frequency
range |
50Hz±3Hz or 60Hz±3Hz |
Power
factor |
0.9
|
Output |
Phase |
Three
phase |
Wave |
Sine
wave |
Voltage |
Low |
5V-150V(L-N) |
High |
10V-300V(L-N) |
Frequency |
47-63Hz,
50Hz, 60Hz |
Frequency
regulation |
≤0.01% |
Max.
current |
High
(A) |
8.3
|
13.9
|
20.8
|
27.8
|
41.7
|
62.5
|
83.3
|
104.2
|
Low
(A) |
16.7
|
27.8
|
41.7
|
55.6
|
83.3
|
125.0
|
166.7
|
208.3
|
System |
Power
regulation |
≤0.5% |
Load
regulation |
≤0.5% |
Total
harmonic distortion (THD) |
2% (linear
load) |
Efficiency |
≧90% |
Response
time |
≦2ms |
Wave
factor |
3:1 |
Protection
device |
Input
no-fuse breaker, output no-fuse breaker, electronic circuit
instant trip for over/low voltage, over
current, over load, over temperature and short circuit
protection and alarm system |
Indicator |
Display |
LCD
(320×240) |
Voltage |
Measure
range: 0~300V; analytic degree: (<100V) 0.01V, (≥100V)
0.1V; accurate degree: 0.5%FS+5COUNT |
Current |
Phase
power≤5kW measure range:
0∼50A;
analytic degree: (<10A )0.001A, (≥10A,<50A)
0.01A; accurate degree: 0.5%FS+5COUNT |
Phase
power>5kW
measure range:0∼700A;
analytic degree:
0.01A;accurate
degree: 0.5%FS+5COUNT |
Power |
Phase
power≤5kW measure range:
0∼5kW;
analytic degree: (<1kW) 0.1W , (≥1kW,≤5kW)
0.001kW; accurate degree:0.5%FS+5COUNT |
Phase
power>5kW
measure range:0∼75kW;
analytic degree: 0.01kW; accurate degree: 0.5%FS+5COUNT |
Frequency |
Measure
range:45∼500Hz;
analytic degree: 0.1Hz; accurate degree:
0.01%FS+2COUNT |
Power
factor |
Measure
range: 0∼1;
analytic degree: 0.01; accurate degree: 2% |
Time |
Measure
range: 1s∼99h;
analytic degree:1s |
Default
item |
Voltage |
Fixed
range: 0∼300V;analytic
degree: 0.1V;accurate
degree: 1% |
Frequency |
Fixed
range: 45∼500Hz;
analytic degree: 0.1Hz;accurate
degree: 0.01% |
Time |
Fixed
range: 1s∼99h;
analytic degree:1s |
General
program memory |
10
sets, for voltage and frequency default value |
Step
program memory |
24
sets, for voltage, frequency and step running time |
Gradual
program memory |
12
sets, for voltage, frequency and gradual running
time |
Revolving
operation function |
Both
step and gradual have revolving function, revolving time can
be set 999999 times |
Control
mode |
Short
range control |
Keyboard
control |
Remote
control |
RS232(standard) |
RS485(standard) |
Environment |
Insulation
resistance |
≥DC500V
10MΩ |
Withstand
voltage insulation |
AC
1800V 10mA/ 1Min |
Cooling
system |
Fan
cooling |
Temperature |
0℃
~ 45℃ |
Humidity |
0~90%
(Non-condensing) |
Altitude |
1500m |
Case
No. |
③ |
④ |
⑤ |
Weight(kg) |
220 |
244 |
300 |
381 |
424 |
580 |
647 |
760 |