Programmable AC Power Source - Three Phase/Three Phase (6~75kVA)

APF-33006 APF-33010 APF-33015 APF-33020 APF-33030 APF-33045 APF-33060 APF-33075

Programmable AC Power Source - Three Phase/Three Phase (6~75kVA)
           
    APF-33006   APF-33015   APF-33045    
    APF-33010   APF-33020   APF-33060    
        APF-33030   APF-33075    
                 

Model

APF-33006

APF-33010

APF-33015

APF-33020

APF-33030

APF-33045

APF-33060

APF-33075

Capacity (kVA)

6

10

15

20

30

45

60

75

Circuit Type

 IGBT/PWM type

Input

Phase

Three phase

Wave

Sine wave

Voltage

220V/380V

Voltage range

220V/380V±15%

Frequency range

50Hz±3Hz  or  60Hz±3Hz

Power factor

0.9

Output

Phase

Three phase

Wave

Sine wave

Voltage

Low

5V-150VL-N

High

10V-300VL-N

Frequency

47-63Hz, 50Hz, 60Hz

Frequency regulation

0.01%

Max. current

High (A)

8.3

13.9

20.8

27.8

41.7

62.5

83.3

104.2

Low (A)

16.7

27.8

41.7

55.6

83.3

125.0

166.7

208.3

System

Power regulation

0.5%

Load regulation

0.5%

Total harmonic distortion (THD)

2%  (linear load)

Efficiency

90%

Response time

2ms

Wave factor

3:1

Protection device

Input no-fuse breaker, output no-fuse breaker, electronic circuit instant trip for over/low voltage,
over current, over load, over temperature and short circuit protection and alarm system

Indicator

Display

LCD 320×240

Voltage

Measure range: 0~300V; analytic degree: (<100V) 0.01V,  (100V) 0.1V; accurate degree: 0.5%FS+5COUNT

Current

Phase power5kW  measure range: 050A; analytic degree: (<10A )0.001A, (10A,<50A) 0.01A; accurate degree: 0.5FS+5COUNT

Phase power>5kW  measure range0700A analytic degree:  0.01Aaccurate degree: 0.5FS+5COUNT 

Power

Phase power5kW   measure range: 05kW; analytic degree: (<1kW) 0.1W , (1kW,5kW) 0.001kW; accurate degree:0.5FS+5COUNT

Phase power>5kW   measure range075kW; analytic degree: 0.01kW; accurate degree: 0.5FS+5COUNT

Frequency

Measure range45500Hz; analytic degree: 0.1Hz; accurate degree: 0.01%FS+2COUNT

Power factor

Measure range: 01; analytic degree: 0.01; accurate degree: 2

Time

Measure range: 1s99h; analytic degree:1s

Default item

Voltage

Fixed range: 0300Vanalytic degree: 0.1Vaccurate degree: 1%

Frequency

Fixed range: 45500Hz analytic degree: 0.1Hzaccurate degree: 0.01

Time

Fixed range: 1s99h; analytic degree:1s

General program memory

10 sets, for voltage and frequency default value

Step program memory

24 sets, for voltage, frequency and step running time

Gradual program memory

12 sets, for voltage, frequency and gradual running time

Revolving operation function

Both step and gradual have revolving function, revolving time can be set 999999 times

Control mode

Short range control

Keyboard control

Remote control

RS232standard

RS485standard

Environment

Insulation resistance

DC500V 10MΩ

Withstand voltage insulation

AC 1800V 10mA/ 1Min

Cooling system

Fan cooling

Temperature

0 ~ 45

Humidity

0~90%  (Non-condensing)

Altitude

1500m

Case No.

Weight(kg)

220

244

300

381

424

580

647

760

Remarks Custom-made specifications are discussible;

All specifications are subject to change without prior notice.