GPM-8212 AC Power Meter
 
 

Contact



GPM-8212

FEATURES :
Simultaneous display of W, A, V (PF or Hz)
True RMS V, A, W
Auto calibration via computer
Max. / Min. / Hold function
High immunity to external noise
CT ratio (1 ~ 9999)
PT ratio (1 ~ 9999)
RS-232 or RS-485 interface (option)
SPECIFICATIONS
Voltage
 Range 5V, 10V, 20V, 40V, 80V, 160V, 320V, 640V total 8 ranges by auto-range or manual
 Measurement Type True rms
 Input Resistance >1M§Ù
 Max. Input Voltage 1000V (peak), 700V (rms)
 PT Ratio Setting 1 ~ 9999
 Accuracy (at 23¢XC+5¢XC)
                      (Sinewave)
+ 0.1% of reading + 0.1% of range

Current
 Range 160mA, 320mA, 640mA, 1.280A, 2.560A, 5.120A, 10.24A, 20.48A total 8 ranges by auto-range or manual
 Measurement Type True rms
 Input Resistance 0.01§Ù
 Max. Input Current 30A (peak), 20A (rms)
 CT Ratio Setting 1 ~ 9999
 Accuracy (at 23¢XC+5¢XC)
                      (Sinewave)
+ 0.1% of reading + 0.1% of range

Watt
 Measurement Range 0.32mW ~13.10kW
 Measurement Type True rms
 Accuracy (at 23¢XC+5¢XC)
                      (Sinewave)
+ 0.2% of reading + 0.2% of range

Power Factor
 Range 0.001 ~ 1.000
 Computation W / (V x A) = Power Factor (PF)

Frequency
 Measurement Range 40Hz ~ 400Hz
 Accuracy (at 23¢XC+5¢XC) + 0.2% of reading

General
 Display 4 digits 0.56" LED and 2 sets of 4 digits 0.4" LED
 Minimum Input 2% of reading
 Response Time 2 cycles/sec
 Overload Indicating " O.L "

Power Source AC 86 ~ 265V, 50/60Hz

Accessories Instruction manual ¡Ñ 1, Power cord ¡Ñ 1
Option : RS-232 or RS-485 with disk

Dimensions & Weight 251(W) ¡Ñ 91(H) ¡Ñ 291(D) mm, Approx. 1.6kg