CP-600.620.660 功率諧波失真分析儀

 

 

     PAGE 1

Computing Functions
Function Apparent Power (VA) Reactive Power (Var) Power Factor (PF) Phase Angle (DEG)
Computation VxA √(VA)2-W2 W/V.A COS-1|PF| 
Range VA Range Va Range 0 to 1 0 to ±90
Display 19999 19999 ±1.0000 ±90.00
Accuracy ±0.001% of VA range ±0.001% of VA range ±0.0001 PF error ±0.01

 

Other Functions
Total Harmonic Distortion (THD)(CP-660-2 CP-660-5 Only)
Ranges (Auto) 10%. 100%
Display resolution 4 digits (0.001% ~ 99.99%)
Frequency Range (Automatic Tuned) 45Hz ~ 65Hz. 370Hz ~ 430Hz
Crest Factors Up to 3
Fundamental Rejection 80db and above
Residual Distortion and noise Less than 0.1% (Sine Wave)
Detection Type (THD-R) (THD-F=THD-R/√(1-(THD-R)2) 頻寬設定為5KHz  True RMS F為第一次諧波
Measuring Input Voltage or Current
Frequency (Hz)
Ranges (Auto 4 Range) 100Hz. 1kHz. 10kHz. 100kHz
Display Resolution / Maximum resolution 5 digits / 0.001Hz
Operating Principle Reciprocal Counting method
Accuracy (23 oC±5 oC) ±0.01% ±1C
Measuring Input Voltage or Current
Peak Voltage (+pk) (-pk) (P-P)
Ranges (Auto or Manual)(7 Range)
CP-600-2  CP-660-2 ±0.6A 1.5A 3A 6A 15A 30A 60A (CP-620-2)
CP-600-5  CP-660-5 ±1.5A 3A 6A 15A 30A 60A 150A
Display Resolution 4-1/2 digits
Frequency Range 10Hz to 100kHz
Accuracy ±1% reading ±1%range ±1%/KHz
Crest Factor (CF)
Ranges 1.000 to 9.999
Frequency Range 10Hz to 100kHz
Accuracy ±1%reading ±1%range ±1%/KHz
Measuring Input Voltage or Current
Inrush Current (Ins)
Ranges (7 Range / Int shunt) 60mA to 60Apk(20A)/150mA to 150A peak(50A)
Accuracy ±3% of selected range
Integrator (INTG)
Function Wh. VAh. VArh. Ah
DIsplay Resoultion 6 digits (Max 999.999M)
Unit m.K.M
Integration Interval 0.3second
Elapsed Time Display 5 digits 1 minute to 999 hours 59 minute
Timer accuracy ±0.01%
Interfaces (Optional)
GPIB Specifications Standard IEEEE 488.2
Function SH1 AH1 T6 L4 SR1 PL1 PP0 DC1 DT1 C0
RS-232 Mode Start stop synchronization
Baud rate 1200. 2400. 4800. 9600bps
Print Port Specifications Standard Centronics (IBM-PC Compatible)
Driver EPSON LQ Series and Compatible
Print Interval 1 second to 24 Hurs(1 second STEP)
Print Count 1~9999
Print Format Panel display or All Parameter