High-speed bipolar power supply (power amplifier) ​​A1110 series

A1110 series (manufactured by HUBERT)

The A1110 series is a wide band, high power bipolar power supply with 4-quadrant output.

·         High speed, high voltage 200kHz, maximum 200Vp-p, 80Ap-p
(40-QE-100 model)

·         Expandable to high voltage/current with series/parallel operation

·         Equipped with excellent safety functions

·         USB standard equipment, LAN (optional)

·         Compact and lightweight space-saving design

 

A1110-40-QE

Output voltage/current expansion

High-voltage and large-current can be supported by connecting the main body in series and parallel. (Up to 600Vp-p/320Ap-p)

[Combination example]

model


Number of parallel connections

Serial
connection number

Maximum
output voltage

Maximum
output current

Slew
rate

Maximum
peak current

A1110-5-x

-

3 units

225V peak

10A peak

240V/μs

27A peak

A1110-16-x

4 units

-

75V peak

105A peak

100V/μs

200A peak

A1110-16-x

-

3 units

225V peak

26A peak

250V/μs

55A peak

A1110-16-x

Two

Two

150V peak

55 peak

175V/μs

55A peak

A1110-40-QE-75/100

4 units

-

75/100V peak

152A peak

80V/μs

300A peak

A1110-40-QE-75/100

-

3 units

225/300V peak

40A peak

240V/μs

80A peak

A1110-40-QE-75/100

Two

Two

75/100V peak

76A peak

160V/μs

152A peak

safety equipment

·         Monitor the temperature of the output amplifier to avoid damaging the product.

·         Any current limitation is possible to avoid damage to DUT and this product.

·         Equipped with interlock function (BNC type)

BNC type

·         Overvoltage protection function (optional)

·         USB/LAN interface with disconnection prevention function

·         *LAN interface is optional

USB / LAN terminal with lock mechanism

·         Check in-flight information via interface

Voltage/current monitor

You can check the applied voltage and current with an oscilloscope. No need for voltage/current probes.

 

CN board (E and QE models only)

RC network compensation circuit for supplying constant load current in wide frequency range in current operation mode.
In addition to 4 types,
you can select from 6 types, including any 2 types
 

Feedback sensor (optional)

KELVIN sense can be selected as the voltage sensor for feedback. In addition, a high-precision current transformer (option) is also available from the shunt resistor (standard equipment) for the current sensor.

Remote software

Full remote control is possible via LAN/USB. Controls such as output ON/OFF, mode switching, change of current feedback constant, setting of current limit, confirmation of machine temperature, safety related settings and confirmation of equipment can be done via interface.

A1110 series specifications

model

A1110-

05-A

05-E

05-QE

16-A

16-E

16-QE

40-QE

40-QE-100V

Power band

DC-200kHz

Small signal frequency band

DC-1MHz

Output voltage range

±75 Vpeak

±75 V peak

±75 V peak

±100 V peak

Output current pressure range

±11 A peak

±28 A peak

±40 A peak

output

Source

500W

1000W

1200W

sink

90W

150W

300W

340W

650W

750W

Output impedance

≤10mΩ

≤60mΩ

TBD

Output
resistance adjustment

-

Output resistance adjustment range: 0 to 200
mΩ Resolution: 1 mΩ Accuracy: 0.5%

-

Output resistance adjustment range: 0 to 200
mΩ Resolution: 1 mΩ Accuracy: 0.5%

Output resistance adjustment range: 0 to 200
mΩ Resolution: 1 mΩ Accuracy: 0.5%

Option-12: Option for output resistance adjustment A1110-XX-E/QE

Slew rate

100V/μs

Possible input
rise/fall time

≥ 20 μs
(pulse rise/fall time must be greater than 20 μs)

Output connector

4mm safety jack

Voltage control
(CV) voltage gain

×10

Current control
(CC) current gain

-

1V/1A

-

1V/3A

1V/10A

Voltage monitor output

-

0.1V/1V

-

0.1V/1V

0.1V/1V

Current monitor output
() is the shunt resistance value

-

0.4V/1A (20mΩ)
1.2V/0.1A (2.5Ω)

-

0.2V/1A (20mΩ)
1.2V/0.1A (2.5Ω)

1V/10A (5.4mΩ)

Power-supply voltage

200V

External dimensions (mm)

About 449Wx
133Hx
435.5D

About 449Wx
133Hx
495D

About 449Wx
133Hx
585.5D

About 449Wx
133Hx
585.5D

mass

About 19kg

About 34 kg

About 37kg

A1110 series option

[Model name]
Option name

A1110- ("x" is not supported)

Remark

05-A

05-E

05-QE

16-A

16-E

16-QE

40-QE

40-QE-100V

[Option02]
Internal sensor

Optional support

Optional support

×

×

Changed current sense from shunt to CT sensor.
Non-contact measurement improves current monitor waveform and feedback characteristics during CC

[Option03]
High stable gain

Optional support

Optional support

Optional support

High stability gain
(±0.1%)

[Option04]
Built-in signal generator

×

×

×

×

Optional support

Optional support

Function generator function added
DC, 0.05Hz-300kHz, sine wave, triangular wave, square wave

[Option05]
Built-in
isolation
amplifier

Optional support

Optional support

Optional support

When expanding the voltage by connecting in series, it reduces common mode noise and secures safety. (Built-in A1340-C1 function)

[Option06]
LAN
interface

×

Optional support

×

Optional support

Optional support

LAN interface with disconnection prevention function

[Option 07]
Voltage/current display

×

×

×

×

Optional support

×

×

Digital display of voltage and current on the front panel

[Option08]
KELVIN sense

×

Optional support

×

Optional support

standard equipment

The influence of wiring can be canceled during CV.

[Option09]
Output ±100V

Optional support

Optional support

×

Standard
equipment

100V power supply expansion option

[Option10]
Internal current sensor

×

×

×

×

×

×

Optional support

Changed current sense from shunt to CT sensor.
Non-contact measurement improves current monitor waveform and feedback characteristics during CC

[Option 11]
Voltage/current display

×

×

×

×

×

×

Optional support

Voltage/current digital display on front panel 3.5 digit LED ± 2% (DC-50 kHz, at 5% or more of full scale) 

[Option12]
Output resistance adjustment

×

Optional support

×

Optional support

Optional support

Output resistance adjustment range: 0 to 200
mΩ Resolution: 1 mΩ Accuracy: 0.5%

[Option13]
LAN interface
face

Optional support

×

×

Optional support

×

×

×

×

LAN interface with disconnection prevention function

[Opiont14]
Overvoltage protection

×

Optional support

×

Optional support

Optional support

The output voltage is constantly monitored, and the output is stopped when the set voltage is exceeded.

[Opiont16]
KELVIN sense

Optional support

×

×

Optional support

×

×

×

×

Sense function

■Parallel connection unit
: For A1110-16 type connection, for A1110-40 type connection

 

■Isolation amplifier
: A1340-C1

 

 

Products list | brand | Model No. | Home

>