CS-10000 Series Specifications
Collector Supply HV mode
Model |
CS-10000 series |
||||||||
Mode/Polarity |
Rectified SINE/+-, DC/+-, LEAKAGE/+-, AC |
||||||||
Max. Peak |
|
||||||||
Max. Peak Power |
120mW/1.2W/12W/120W/390W** (**390W is not available at 3kV range) |
||||||||
Horizontal range |
50mV to 500V/div |
* Available peak current can be varied with test conditions. Measurement can be done within peak pulse current in above.
Collector UHV mode
Model |
CS-10400 |
CS-12800 |
CS-15800 |
||||||||||||
Mode/Polarity |
Pulse + - |
||||||||||||||
Max. Peak |
|
|
|
||||||||||||
Max. Peak Power |
40W / 400W / 4kW |
32W / 320W / 3.2kW |
40W / 400W / 4kW |
Collector HC mode
Model |
CS-10400 |
CS-10800 / CS-12800 / CS-15800 |
||||||||||||||||||
Mode/Polarity |
Pulse + - |
|||||||||||||||||||
Max. Peak Current |
|
|
||||||||||||||||||
Pulse width |
50μs to 900μs , 50μs to 1,200μs(at 8,000A range)(10μs resolution) |
|||||||||||||||||||
Measurement point |
Measurement point can be
specified. (Resolution :10μs) |
|||||||||||||||||||
Vertical range |
100mA to 1,000A/div |
Common Specifications
tems |
Descriptions |
||
Loop Compensation |
Hardware compensation |
Correction of floating capacitance between collector supply and ground |
|
Software compensation |
Simulated loop procedure by software thinning process |
||
Step Generator |
Offset |
Range |
+/- 10times of STEP AMPLITUDE setup |
Resolution |
1% STEP AMPLITUDE setup |
||
Current mode |
Range |
21 steps at 50nA/step to 200mA/step, 1-2-5 switchable |
|
Current |
2A, max. |
||
Voltage |
10V,max. or more |
||
Voltage model |
Range |
6 steps at 50mV/step to 2V/step, 1-2-5 switchable |
|
Current |
500mA to (to 8V), max. , 200mA to (to 15V), max.,10mA to ( to 40V), max. |
||
Voltage |
+/-40V, max. |
||
Step rate |
Twice of 50Hz or 60Hz (the same rate when AC mode), Pulse interval when HC mode |
||
Pulse step |
Pulse |
50μs to 400μ(10μs /step) |
|
width |
When HC mode set, approx.100μs wider-pulse width against collector supply pulse |
||
Number of steps |
0 to 20 steps |
||
AUX output |
Range |
OFF,-40V to +40V (variable at 100mV / step) |
|
Measurement Mode |
REPEAT,STOP / SINGLE,SWEEP |
||
Vertical axis |
Collector current |
Range |
HV mode : 20 step at 1μA/div to 2A/div, 1-2-5 switchable (except HC model) |
Accuracy |
2% of readings +
0.05×VERT/div adding loop compensation error as follows; |
||
Emitter current |
Range |
20 steps at 1nA/div to
2mA/div, 1-2-5 switchable |
|
Accuracy |
2% of readings +0.05×VERT/div+1nA or below |
||
Horizontal axis |
Collector voltage |
Range |
HC mode : 7 steps at 50mV/div to 5V/div, 1-2-5 switchable (except HV mode) |
Accuracy |
2% of readings + 0.05×HORIZ/div or below |
||
Base / |
Range |
7 steps at 50mV/div to 5V/div, 1-2-5 switchable |
|
Accuracy |
2% of readings +0.05×HORIZ/div or below |
||
Display |
Display |
8.4 inch TFT LCD |
|
Number of data |
1,000points/trace at AC
and Rectified SINE |
||
Trace display |
Interpolation display between points, Dot display |
||
Average |
OFF, 2 to 255times |
||
Persistence |
OFF, SHORT, LONG, infinite |
||
Internal waveform memory |
4 kinds |
||
Cursor measurements |
DOT |
Vert, Horiz, β or gm |
|
fLINE |
Vert, Horiz, 1/grad, intercept |
||
FREE |
rt, Horiz, β or gm |
||
WINDOW |
Vert, Horiz, β or gm in WINDOW area |
||
Remote |
Remote on LAN 10BASE-T/100BASE-TX 1 port |
||
Power supply |
CS-3000,CS-5000 |
AC100V-AC240V 50/60Hz, Max Power:500VA (operation), 7W Max (save mode) |
|
CS-10000 |
AC200V single phase 50/60Hz, Max Power:10kVA (operation) |
||
External dimensions (mm) |
CS-3100,CS-5100 |
424W x 555D x 220H, approx. 28kg |
|
CS-3200,3300 |
424W x 555D x 354H, approx. 43kg |
||
CS-10400,CS-10800 |
1,110W x 1,150D x 1.216H, approx. 370kg |