DS-5424 |
DS-5422 |
DS-5414 |
DS-5412 |
||
Frequency bandwidth(-3dB) |
200MHz |
100MHz |
|||
Rise time(Typical)) |
750ps |
1ns |
|||
Input Channel |
4 |
2 |
4 |
2 |
|
Maximum Sampling Speed |
1GS/s(all CHs)/ 2GS/s(Channel combined) |
1GS/s(all CHs) |
|||
Equivalent Sampling Rate |
100GS/s |
||||
Peak detect resolution |
1ns |
||||
Averaging |
2 to 256 times |
||||
Maximum Memory Length |
500kpts/ch(for all CHs) |
||||
Vertical Resolution |
8-bit |
||||
Input voltage range |
2mV/div - 10V/div(1MΩ) |
||||
Offset voltage |
2mV/div -
50mV/div : ±1V |
||||
DC gain accuracy |
±1.5% + (0.5% of fullscale) |
||||
Maximum Input Voltage |
±400Vpeak CAT I (1MΩ) |
||||
Band-limiting filter |
Analog form : 20MHz,2MHz,200kHz |
||||
Input coupling |
GND, DC 1MΩ, AC 1MΩ |
||||
Input Impedance |
1MΩ±1.5% //20pF |
||||
Probe sense |
Automatic: 1:1、10:1、100:1、1000:1 |
||||
Timebase |
2ns/div ∼ 50s/div |
5ns/div ∼ 50s/div |
|||
Standard probe |
SS-0130R (multi-channel) |
||||
Roll mode |
50ms/div ∼ 50s/div (100kS/s max) |
||||
Timebase (Clock) accuracy |
±10 ppm |
||||
Trigger function |
|||||
Trigger type |
Edge, Pulse Count, Pulse Width, Period, Dropout, TV |
||||
TV mode / |
NTSC, PAL, Custom / upto 3,000 / 1, 2, 4 & 8 fields |
||||
Pulse Count Trigger |
1 to 9999 events |
||||
Pulse Width Trigger |
15ns to 50s |
||||
Period Trigger |
40ns to 50s |
||||
Dropout Trigger |
50ns to 50s |
||||
Pattern Trigger |
- |
||||
Trigger source / |
- |
||||
Trigger Source |
Input CHs, Line, EXT(+/-0.5V), EXT10(+/-5.0V) |
||||
Trigger Slope /Coupling |
+,- / AC, DC, HF Rej, LF Rej, Noise Rej |
||||
Display function |
|||||
Display size/ resolution |
7.5inch color TFT-LCD with Touch screen / VGA(640*480pixels) |
||||
Display mode |
YT、XY、XY (Triggered) |
||||
Vector Display Method |
Interpolation on sample points or Dots |
||||
Analog persistence mode |
Monochrome grayscale or Color Spectrum |
||||
Persistence time setting |
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s & Infinite |
||||
Reference waveform memory |
5 waveforms |
||||
Panel setting memory |
5settings for Internal memory or USB memory |
||||
Parameter measurement, Cursor, Zoom, Calculation, Replay |
|||||
rameter measurement |
Maximum, Minimum, Peak-Peak, RMS, Cycle RMS, Mean, Cycle Mean, Top, Base, Top-Base, +Overshoot, -Overshoot, Tr 20-80%, Tf 80- 20%, Tr 10-90%, Tf 90-10%, Freq., Period, +Pulse Count, -Pulse Count, +Pulse Width, -Pulse Width, Duty Cycle, Integral, Skew (+, -), Skew at level |
||||
Concurrent number of measurements / |
Four parameter maximum /Max (Maximum), Min (Minimum) ,Num (Number of the total waveforms) |
||||
Logging item, destination |
- |
||||
Pass/Fail |
- |
||||
Cursor |
Time, Amplitude, Time and Amplitude, Value at cursor |
||||
Zoom |
Zoom key enable display at individual grid area |
||||
Calculation |
Addition, Subtraction, Multiplication, FFT(8k points maximum, RECTANGULAR, HANNING, FLATTOP) |
||||
Rescaling / Unit conversion |
a*x+b(x: input voltage at User defined a and b) / Volt, Ampere, Watt, degree and unit-less |
||||
Replay |
Automatic waveform recording upto 1,024waveforms, History Replayable |
||||
Counter |
6-digit |
||||
Interface (standard) |
USB 2.0(Host&Device), LAN(100Base-TX), GPIB(Factory option: DS-576) |
||||
AUX Interface |
AUX connector for External options |
||||
DS-577 AUX IO CH1/CH2 output |
- |
||||
DS-578 AUX IO CH1/TRIG output |
- |
||||
DS-576 GPIB interface |
GPIB: IEEE488.2 (factory option) |
||||
DS-579 probe power supply options |
Our active probe power supply (2 systems) |
||||
Waveform Data Storage |
USB memory for Binary, ASCII, Mathcad, Calculation(ASCII) & Calculation(Mathcad) |
||||
Hardcopy Output |
Output form front panel USB port to USB memory in TIFF, BMP & PNG format or Output to PictBridge Printers |
||||
Calibration signal output |
Square waveform at 1kHz, 3Vp-p |
||||
Power / power consumption |
AC 90Vrms to 240Vrms, 47Hz to 63Hz, AC 90Vrms to 132Vrms, 380Hz to 420 Hz, 95VA max (60W max) |
||||
Dimensions (mm) / Weight |
Approx. 330W × 190H ×124D / Approx. 3.7kg |
||||
Environmental condition |
|||||
Performance guarantee temperature |
+10℃ to + 35℃ |
||||
Operation temperature and humidity / |
0deg. to
+40˚C at 5 to 80%(RH<=30˚C) and 55%RH or less at 40˚C non-condensation / |
||||
Accessory |
|||||
Probe(multi-channel), Power cord, Front panel cover, CD-ROM(Instruction Manual, Remote Control Manual), User's Guide |
|||||
Factory options |
|||||
GPIB Interface |
GPIB: IEEE488.2 (factory option) |
||||
2 ways optional for Probe Power
supply |
Our active probe power supply (2 systems) |