Hall element type current probe SS-270 / SS-260 / SS-250 / SS-240A

Current Probes SS-250/SS-240A

SS-250/SS-240A

              SS-250 / SS-240A main unit power supply is required separately)

 

Compatible with various applications

 

It is effective for wideband and current waveform observation of switching power supplies, optical disk manufacturing lines, semiconductor power devices, etc.

Main features

Low noise characteristics for easy observation of milliamperes order

Wide band DC to 100MHz (SS-250)/DC to 50MHz (SS-240A)

Achieves high sensitivity and wide band by adopting thin film Hall element

Models equipped with a power supply for probes that can be directly powered from an oscilloscope TS -81000, TS-80600, SS-7840H, SS-7840, SS-7830, TS-8500, SS-7825

Clamp type for easy measurement without disconnecting the electric circuit

Equipped with simple protection function for excessive input

Can be used with measuring instruments that do not have a  probe power supply

 ( power can be supplied by the optional probe power supply PS-26 )

Product Specifications

item

SS-250

SS-240A

frequency band

DC to 100MHz (-3dB)

DC to 50MHz (-3dB)

Maximum allowable input current

30A rms (maximum input range), 50A peak (maximum peak current) non-continuously

Output sensitivity

0.1V/A

Accuracy of sensitivity

0 to 30A rms, DC and
 ± 45 % AC 45 to 66Hz ±1.0% of reading ±10mA (with probe alone)
Over 30A rms and 50A peak or less,
 ±2.0% of DC and AC 45 to 66Hz reading (in probe only)

noise

2.5mA rms or less (observed with an oscilloscope with a bandwidth of 20MHz)

power consumption

5.3VA max

5.6VA max

Power-supply voltage

±12V ±0.5V

Operating temperature and humidity range

0 to +40, 80%RH or less (no condensation)

Storage temperature and humidity range

-10℃∼+50, 80%RH or less (no condensation)

Operating altitude

Altitude 2000m or less (atmospheric pressure about 79kPa) Indoor

Effect of external magnetic field

5mA maximum (DC and 60Hz, 400A/m AC magnetic field)

20mA maximum (DC and 60Hz, 400A/m AC magnetic field)

Maximum circuit voltage used

300V, CAT I (insulated conductor)

Measurable conductor diameter

φ5 mm

Cable length

Sensor cable

About 1.5m

power cable

About 1m

size

Sensor part

Approx. 175W x 18H x 40D mm

Termination section

About 27W x 55H x 18D mm

mass

About 240g

About 230g

Compliant standard

safety

EN61010-2-032:2002
Measurement category I (expected transient overvoltage 1500V),
pollution degree 2

EMC

EN61326:1997+A1:1988+A2:2001

accessories

Instruction manual (1), hard case (1)

*

Items related to performance and accuracy are 23°C ± 5°C, and 30 minutes after power is turned on.

Characteristic diagram

SS-250 Continuous maximum input range (frequency derating)

SS-250 continuous maximum input range graph

SS-240A Continuous maximum input range (frequency derating)

SS-240A continuous maximum input range graph

*

It can be used as it is for the model that has the power supply terminal for the active probe in the oscilloscope body. In addition, for models that do not have a power supply terminal for active probe, you can use this current probe by using a separately sold power supply (PS-26).

*

If the input BNC terminal of the oscilloscope is buried in the outer case and the SS-250/SS-240A connection is obstructed (Our product is Simplified King), please prepare a conversion BNC plug for the jack plug. ..

*

When the SS-250/SS-240A is used with an oscilloscope equipped with a probe power supply and the measured current value is large, the current probe power supply PS-26 may be required.

*

If the measured current value is large, the PS-26 power supply for current probe may not be able to use two SS-250/SS-240A simultaneously.

Note

1.

To avoid short circuit and personal injury, please use this product on the electric circuit below the maximum operating circuit voltage.

2.

Do not use with bare conductors to avoid a short circuit or personal injury when the tip of the clamp core is opened.

Power Supply PS-26 for SS-270 / SS-260 / SS-250 / SS-240A / SS-240

PS-26

This is the current probe power supply used when measuring with an oscilloscope that does not have an active probe power supply.

Performance

Compatible current probe

SS-270 / SS-260 / SS-250 / SS-240A / SS-240

Number of power connectors

2

Output voltage

±12V ±0.5V

Output current

Maximum 600mA (sum value of each channel)

Operating temperature and humidity range

0 to +40, 80%RH or less (no condensation)

Storage temperature and humidity range

-10℃∼+50, 80%RH or less (no condensation)

Operating altitude

Indoor up to an altitude of 2000 m

Power-supply voltage

AC100V (120V, 220V, 240V can be set)
(The voltage fluctuation of
±10% against the power supply voltage is taken into consideration.)

Rated power frequency

50Hz / 60Hz

power consumption

Up to 20VA

External dimensions

About 73W x 110H x 186D mm

mass

About 1.1 kg (excluding accessories)

Compliant standard

safety

EN61010-1: 2001, Pollution degree 2

EMC

EN61326:1997+A1:1998+A2:2001, EN61000-3-2:2000
EN61000-3-3:1995+A1:2001

accessories

Power cord (1), instruction manual (1), spare fuse (1)
, 100V/120V, shipping: 100V, 120V F1.0 AL/250V,
φ5×20mm
, 220V/240V, shipping: 220V, 240V F0.5 AL/250V,
φ5×20mm

*

If the measured current value is large, it may not be possible to use two simultaneously.

Current Probes SS-270/SS-260

   
  
SS-270 / SS-260 main unit (POWER SUPPLY IS REQUIRED SEPARATELY)

Main features

High current 150A, 500A compatible model

Large diameter clamp type current measurement

Clamp type that can be easily measured without cutting the path

Equipped with simple protection function for excessive input

Can be used with measuring instruments that do not have
probe power supply ( power can be supplied by the optional probe power supply PS-26 )

High sensitivity due to adoption of thin film Hall element

Product Specifications

item

SS-270

SS-260

frequency band

DC to 2MHz (-3dB)

DC to 10MHz (-3dB)

Maximum allowable input current

500A rms (maximum input range)
700A peak (maximum peak current) non-continuously

150A rms rms (maximum input range)
Discontinuous 300A peak (maximum peak current)

Output sensitivity

0.01V/A

Accuracy of sensitivity

Up to 500 Arms
±1.0% of reading ±5 mV
(with probe alone)
Beyond 500 Arms

±700% peak or less, ±2.0% of reading in the range of DC and AC45 to 66Hz
(in probe only)

Up to 150 Arms
±1.0% of reading ±1 mV
(with probe alone)
Beyond 150 Arms

±2.0% of reading within 300A peak, DC, and AC45 to 66Hz
(in probe only)

noise

25mA rms or less (observed with an oscilloscope with a bandwidth of 20MHz)

power consumption

7.2VA max

5.5VA max

Power-supply voltage

±12V ±0.5V

±12V ±1V

Operating temperature and humidity range

0 to +40, 80%RH or less (no condensation)

Storage temperature and humidity range

-10℃∼+50, 80%RH or less (no condensation)

Operating altitude

Altitude 2000m or less (atmospheric pressure about 79kPa) Indoor

Effect of external magnetic field

800mA maximum
(DC and 60Hz, 400A/m AC magnetic field)

Maximum 150mA equivalent
(DC and 60Hz, AC magnetic field of 400A/m)

Maximum circuit voltage used

600V, CAT II (insulated conductor)

Measurable conductor diameter

φ20 mm

Cable length

Sensor cable

About 2m

power cable

About 1m

size

Sensor part

About 176W x 69H x 27D mm

Termination section

About 27W x 55H x 18D mm

mass

About 520g

About 500g

Compliant standard

safety

EN61010-2-032 :2002 B type
measurement category II, III
(expected transient overvoltage 4000V), pollution degree 2

EMC

EN61326-1: 2006

accessories

Instruction manual (1), case (1)

Instruction manual (1), case (1)

 

 

Products list | brand | Model No. | Home