High-voltage Probes

High-voltage Probes SS-0170R / SS-0171R

SS-0170R / SS-0171R

SS-0170R / SS-0171R


SS-0169
BNC adapter SS-0169
(Option)

SS-0170R Derating curve

SS-0170R Derating curve

 

SS-0171R Derating curve

SS-0171R Derating curve

High-voltage Probes SS-0170R / SS-0171R Specifications

item

SS-0170R

SS-0171R

Input enduring voltage
*Derating curve reference

CAT6,000V(DC+AC peak)
CAT
1,000VDC+AC peak

CAT4,000V(DC+AC peak)
CAT
1,000VDC+AC peak

Frequency bandwidth

DC to 400 MHz(±2 d) *Derating curve reference

Attenuation ratio

100:1±3.0 % 以内

Input impedance

66.7 MΩ±2 %//4 pF 以下

Capacitance(Waveform compensation range)

6 pF to 18 pF

Connector

BNC type

Total length / Weight

Approx.2.0 m / Approx.88 g

Environment conditions

Guaranteed temperature range

5°C to 40 °C(no dew condensation)

Guaranteed humidity range

Humidity of 80% at temperature of 31°C or less and relative humidity linearly reduced up to 50% of the humidity at 40°C

Operating temperature range

-10°C to 50 °C(no dew condensation)

Storage temperature range

-20°C to 70 °C(no dew condensation)

High-voltage Probes SS-0170R / SS-0171R Accessories

SS-0170R / SS-0171R composition

Items

Quantities

Retractable hook tip

1

Ground lead

1

Color rings (red, yellow, blue, and green)

4 x 2

Dolphin clips (red and black)

2 x 1

4mm Probe adaptor with plug

1

4mm Ground lead with plug (black)

1

Adjusting screw-driver

1

Instruction manual (this document)

1

High-voltage Probe HV-P60A

High-voltage Probes HV-P60AHV-P60A

High-voltage waveforms of up to DC 60 kV, pulse 80 kV measured by oscilloscope

Wide bandwidth, DC to 50 MHz

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications

Maximum input voltage

DC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse wave

Bandwidth

DC to 50 MHz, within -3 dB

Rise time

7 ns or less (for probes only)

Input RC

1,000 MW ±5% //5 pF ±2 pF

Attenuation

2000:1 ±5%

Cable length

Approx. 4 m

Connector

BNC type

Used for

Oscilloscope with input RC: 1 MW, 10 to 40 pF

Weight

Approx. 3.2 kg (including accessories)

Accessories

Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag

Options

High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60A/60 and the HV-P30A/30. It is attached by turning the probe bracket upside down (for HV-P60A/HV-P60/HV-P30A/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1.

Characteristic curve

Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P60A]

Dimensions

Appearance

High-voltage Probe HV-P30A

HV-P30A
HV-P30A

High-voltage waveforms of up to DC 30 kV, pulse 40 kV measured by oscilloscope

Wide bandwidth, DC to 50 MHz

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications

Maximum input voltage

DC 30 kV or DC + AC peak*
Single-shot pulse of 40 kV, repetitive signal

Bandwidth

DC to 50 MHz, within -3dB

Rise time

7 ns or less

Input RC

100 MW ±5% //7 pF or less

Attenuation

1000:1 ±5%

Cable length

Approx. 3 m

Connector

BNC type

Used for

Oscilloscope with input RC: 1 MW, 10 to 40 pF

Weight

Approx. 2.5 kg (including accessories)

Accessories

Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag

Options

High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60A/60 and the HV-P30A/30. It is attached by turning the probe bracket upside down (for HV-P60A/HV-P60/HV-P30A/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 30 kV, and the attenuation is 1000:1.

Characteristic curve

Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P30A]

Dimensions

Appearance

 

 

Products list | brand | Model No. | Home