Universal counter SC-7217A / SC-7215A                 TOP

Click on the image to enlarge.

Maximum 3GHz (SC-7217A) Maximum 12 digits/second display 


Easy-to-use 1 key, 1 action, system adopted.
In addition to frequency and period, the universal counter has time intervals, pulse widths, phases, frequency ratios, duty ratios, cumulative counts, and peak voltage measurements, making it easy to perform a variety of measurements. As a basic measuring instrument for development work and technical education, it is also ideal for introduction to production and inspection lines.



Easy operation with 1 key and 1 action.

The efficiency of line inspection work can be easily done by the comparison and statistical calculation functions.

Unit conversion (rotation speed, speed, etc.) is possible with the scaling calculation function.

Easy to confirm waveform amplitude by measuring peak voltage of input signal

Improve efficiency of routine inspection work by saving/recalling panel setup

Equipped with USB, LAN and digital I/O as standard

Highly expandable option group

• RS-232, GPIB interface
• USB host interface
• High stable clock option

Measurement function

Measurement function

SC-7217A

SC-7215A

Gate

internal

EXT-B

MANUAL

SGL

internal

EXT-B

MANUAL

SGL

FREQ-A

frequency

×

×

FREQ-B

frequency

×

×

×

×

FREQ-LINE

frequency

×

×

×

×

×

×

FREQ-C

frequency

×

×

×

×

×

×

PERI-A

Period

×

×

DUTY-A

Duty

×

×

×

×

PW-A

pulse width

×

×

×

×

TOT-A

Counting

×

×

T.INT AB

interval

×

×

×

×

FREQ A/B

Frequency ratio

×

×

×

×

×

×

PHAS AB

Rank

×

×

×

×

: Selectable ×: Invalid : Invalid for 10μ, 100μ, 1ms, 10ms

Universal counter SC-7217A / SC-7215A     Specifications

SC-7217A

SC-7215A

CH-ACH-B

Input impedance

50Ω±1.5% / 1MΩ± 1.5% //16pF ±3pF

Input withstand voltage

50Ω / 1MΩ

7Vrms / 200Vpk

Frequency band

DC / AC

DC ~ 450MHz / 10Hz ~ 450MHz

Input voltage range

ATT OFF / ON

±2.5V / ±50V

Trigger level accuracy

ATT OFF / ON

±2%±25mV / ±2.5%±500mV

Slope switching/Band limitation/Noise rejection

+/- / 10kHz / OFF/ON

EXT-B

Input signal range

Pulse width / Frequency

500ns min / 1MHz max

CH-C

Input impedance / SWR / Maximum input electrical power

50ohm, AC coupling / 2.0 or less / +30dBm

-

Frequency BW

100MHz ~ 3GHz

-

AGC

OFF / ON

-

Burst detection

OFF / ON

-

Detection sensitivity / Burst detection delay time

~ 1.2GHz: -20dBm, ~ 3GHz: -10dBm /10μs

-

Measurement Functions

FREQ AFREQ B

Max. 12-digit/sec (at 1second gate)

Measurement range

Single: 6mHz ~ 250MHz, time / EXT-B gate: 12mHz~450MHz

(Cycle of measured signal should be 1/3 of gate time or less)

Gate selection

Single / EXT-B / Time (set at 10μs to 10s 10^n) (n: integer)

FREQ C

Max. 12-digit/sec (at 1second gate)

-

Measurement range / Gate selection

100MHz ~ 3GHz, 1/16 pre-scaler

-

FREQ LINE

Measurement range / Gate selection

45Hz to 440Hz / 0.1s/1s/10s  (More information is available on “Time gate”.)

PERIOD A

Measurement range

Single: 4ns ~ 166s

(Cycle of measured signal should be 1/3 of gate time or less)

Time / EXT-B gate: 2.2ns to 83s

Gate selection

Single / EXT-B / Time (set at 10μs to 10s 10^n) (n: integer) (More information is available on “Time gate”.)

DUTY A

Input signal range

Pulse width / Frequency

6ns min / 80MHz max

Measurement range

Single / Time

0.01μ ~ 99.999,999,99% /0.2μ to 99.999,999,8%

Gate selection

Single / Time (More information is available on “Time gate”.)

PULSE WIDTH A

Input signal range

Pulse width / Frequency

6ns min / 80MHz max

Measurement range

Single / Time

6ns ~ 171s / 6ns to approximately 1/2 gate time

Gate selection

Single / Time (More information is available on “Time gate”.)

TIME INTERVAL A→B

Input signal range

Pulse width / Frequency

6ns min / 80MHz max

Measurement range

Single / Time

6ns ~ 10,995s / 6ns to approximately 1/2 gate time

Gate selection

Single / Time (More information is available on “Time gate”.)

FREQ A/B

Input signal range / Frequency

250MHz max

Measurement range / Gate selection

1 E-9 to 1 E+9 / Time (set at 10μs to 10s 10^n) (n: integer)

PHAS A->B

Input signal range

Pulse width / Frequency

6ns min / 80MHz max

Measurement range

Single / Time

0.1μ ~ 359.999,999,9°/ 1μ ~ 359.999,999°(Cycle of measured signal should be 1/2 of gate time or less)

Gate selection

Single / Time (Please see “Time gate” for more info. for this)

TOT A

Input signal range

Pulse width / Frequency

2ns min / 250MHz max

Gate selection / Measurement range

MANUAL / EXT-B / Time (More information is available on “Time gate”.) /0 ~ 4,294,967,295 counts

Peak voltage measurement

Frequency / Speed

150Hz ~ 150MHz / 2 seconds or less

Voltage

ATT OFF / ATT ON

±2.5V / ±50V

Measurement operations

Repeat / Single / HOLD / Smoothing (moving average), scaling, comparison, statistics (MAX, MIN, σ, average)

Panel setup / Saving

Internal memory (10) or USB memory / MAX. 500,000kinds (volatile memory)

Internal standard clock

Temperature characteristics

±1ppm (range of 0to +40 with +25 as the standard)

Temperature change / Short-time stability

±0.1ppm/month±1ppm/year / ±1ppb/s

Interface

USB  LANDIO

USB2.0 HS / 100base-TX / Output: HI/LO/GO/BUSY

10MHz STD IN

Input impedance / Input frequency / Input sensitivity

850Ω (10MHz)  AC coupling / 10MHz ±50Hz / 100mVrms

Marker / STD output

STD / Marker selected and output with the setting

Output impedance / Marker output / STD output

50Ωs ±10% / +1Vo-p (0V output during measurement) / 10MHz sine wave 1Vp-p or more (with 50Ωs at the terminal)

Options (Factory Option)

OCXO

(High stable clock)

SC-715

Temperature characteristics

±20ppb (range of 0 to +40 with +25 as the standard)

 Aging rate

±10ppb/day (Frequency change a day on the basis of the frequency 48 hours later. At +25.)

±100ppb/year (Frequency change of one year on the basis of frequency 10days after the power supply injection. At +25.)

SC-716

Temperature characteristics

±5ppb (range of 0 to +40 with +25 as the standard)

Aging rate

±0.5ppb/day (Frequency change of one year on the basis of frequency 30days after the power supply injection. At +25.)

±50ppb/year (Frequency change of one year on the basis of frequency 30days after the power supply injection. At +25.)

Interface

SC-711: GPIB (confirming to IEEE488-1 with full remote functions)

SC-714: RS-232
SC-713: host for connecting the USB

memory (for storage only)

Power Supply

Voltage / Frequency

100V ~ 240V ±10% / 50 ~ 60Hz±5% (100V~240V) /

400Hz±:10% (100V~120V)

Power consumption

70VA(35W) max

Rear panel inputs (optional, factory installed)

SC-709: CH-A/CH-B Rear input for SC-7215A
SC-710: CH-A/CH-B/CH-C Rear input for SC-7217A

External dimensions

210W×99H×353D (mm)/3kg

Accessory

Product users’ guide x 1, instructions (CD) x 1,
power cable x 1.

Environment

0 to 40 with 80%RH or less and no condensation

 

 

Products list | brand | Model No. | Home