The MWJ-6392EU was commercialized in order to contribute rationalization of
instruments on production line by modifying MWJ-6392E into a board type. |
Input Section |
Input signal |
EFM Plus signal (RF or Binary signal)
(Binary signal is not acceptable at EQ-on) |
Input level range |
0.3Vp-p to 3Vp-p |
Input impedance |
Approx. 1M£[ |
Measuring Section |
Measuring clock frequency range |
25.9 to 27.5MHz |
Measuring range |
10% and 20% |
Measuring edge (Polarity) |
+, - and ¡Ó of input signal |
Equalizer |
Conforms to JIS¡Ñ6241
3.2dB¡Ó0.2dB (at 5.16MHz of 27MHz clock frequency) |
PLL circuit |
Conforms to JIS¡Ñ6241 |
Input/output terminal |
RECORDER output |
10%/V (10% range) and 20%/V (20% range)
Max. 2V, ¡Ó0.05V (open circuit) |
MONITOR output |
-6dB to input signal, ¡Ó1dB (50£[ load) |
INHIBIT input |
TTL level (Active low) |
REMOTE terminal |
Connector for remote-control |
Others |
Power requirements |
AC 100/120V to 220/240V ; 15VA |
Operating temperature range |
0ºC to +40ºC |
CONNECTOR |
Case outer dimensions |
222 (W) ¡Ñ 132 (H) ¡Ñ 23 (D) mm |
|
|