Wide bandwidth / High voltage differential probe BumbleBee® (PMK GmbH - Germany)

High voltage differential probe SS-320

High voltage differential Paired probe for PDD series (PMK GmbH - Germany)

 

 

Differential probe / Paired probe

Wide bandwidth / High voltage differential probe BumbleBee® (PMK GmbH)

Wide bandwidth DC - 400MHz

 

Widebandwidth / High voltage differential probe

BumbleBee® Accerrories *5

BumbleBee_Accessories

BumbleBee® Specifications *1

Item

Specification

Attenuation (switchable)

50:1

100:1

250:1

500:1

System Bandwidth
(-3dB)

Input Voltage 50V

300MHz

400MHz

Input Voltage 500V

-

300MHz

Input Voltage 1,000V

-

300MHz

Risetime
(10% - 90%)

Input Voltage 50V

1.2ns

875ps

Input Voltage 500V

-

1.2ns

Input Voltage 1,000V

-

1.2ns

Noise (rms) *2
(Referred to the input)

55 mV

75 mV

Typical Propagation Delay

10 ns

Max. Input Voltage

measurement category

2,000 V rms

6,000 V transient Overvoltage

measurement category

1,000 V rms CAT

Pollution Degree

2

Max. Differential Input Voltage
(incl. AC peak)

± 200 V DC

± 400 V DC

± 1,000 V DC

± 2,000 V DC

Common Mode Voltage

± 2,000 V pk (± 1,400 V rms)

DC Gain Accuracy

± 0.7%

± 0.35%

Offset Range *3

± 4 V

Offset Resolution *3

15 Bit / Minimum Step < 125 μV

Offset Drift *3

150 μV/ºC

40 μV/ºC

Input Impedance

Each Input to Ground

5 MΩ // 4 pF

Differential Input Impedance

10 MΩ // 2 pF

Input Coupling of the Measuring Instrument *4

50 Ω

Typical CMRR

DC

> 80 dB

100 kHz

> 70 dB

1 MHz

> 62 dB

3.2MHz

> 50 dB

Probe power supply


PS-02 (2ch) , PS-03 (4ch)

Probe power supplies provides PC remote control on Bumble Bee via USB or Ethernet(Optional) with PC-software "PMK Probe Control(64bit-Win7 or above version)" with USB memory.

Mechanical Specifications

Weight
(probe only)

370 g

Cable Length

2m

Input Lead Length

25cm

Input Lead Connectors

2 x 4 mm (male)

IOutput Connector

BNC (male)

Environmental Specifications

Altitude

operating : up to 2,000 m

 non-operating : up to 15,000 m

Temperature Range

Probe

operating : 0 °C up to 50 °C
non-operating : 20 °C up to 70 °C

Input Leads

operating : -40 °C up to 85 °C

Maximum Relative Humidity

80 % relative humidity for temperatures up to 31° C,
decreasing linearly to 40 % at 50° C

*1 Measured at 23°C environment connected to PS-02/PS-03 power supply(optional)
*2 Broadband Noise, Bandwidth 30 MHz
*3 Referred of output
*4 Must be met to achieve best performance and avoid Damage to the Probe
*5 Parts#890-880-104 : Twinholder M6 and 890-880-112 : Pair of Rail Clip Connectors 4mm are optional.