Type 1600HM     Headset Auto testing Instrument

Catalogue

 

Main Functions

The following items of headset can be measured:

(1)     Headphone portion:

Test the Frequency Response (20Hz ~ 20 KHz), Sensitivity, ACZ, DCR, Harmonic Distortion, Polarity as well as the Balance testing of both the left and right earphones of the headphone respectively.

(2)     Microphone portion:

Test the Frequency Response (100Hz ~ 8 KHz) ,Sensitivity, DC Current of ECM, Harmonic Distortion of the Microphone, also provide the DCV and load resistor required for ECM testing.

(3)     Automatic switching the left earphone, right earphone and the microphone of the headset for auto testing and auto judging Go/ No-Go.

(4)     All the testing items indicated on items 4 and 5 can be tested individually(R&D or QA use), or all the items (or selected items) can be tested in automatic sequential form (Suitable in production line /QC use).

 

 

The fundamental combination of Type 1600HM

Item

Model No.

Description Usage

1.

160 A

Electro acoustic Analyzer

Mainframe. To control  and process the inputoutput signal.

2.

Monitor &

Keyboard

High Resolution Color Display Monitor & Keyboard

Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax.

3.

181

Headset Testing Controller

Combines with 160A mainframe, automatic switching the left and right earphone and microphone, to test the various electrical characteristics of the earphone, microphone etc.

4.

142 ES

Artificial Ear ( 142ES = IEC - 318 )

Receives the sound generated from the headphone. 142ES is more suitable than Model-142EA-S for testing the headphone, since its frequency range is wider.

5. 142FS

Headset Test Fixture

To position the headset. Placed with two sets of 142ES artificial ear.  The relative position of the 142EA and 140M comply with the ITU international standard.

6. 140M

Artificial Mouse

Generated a flat and stable, precise sound field, for testing the “Microphone”

7.

X-Y Mouse

Mouse

Replace the upward, downward, leftward, rightward and enter keys on the keyboard.

8.

HP Printer

( Option )

Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.)

Print out the tested results & data.

Note 1: 2 sets of Model-142ES and Model-142FS are inseparable; user should buy all at one time.

Note 2: Type 1600HS = Items 1~5 of the above table, which can test only the headphone portion of the headset , and can’t

test the microphone portion.

 

Note 3: Type 1600HM = Items 1~6 of the above table, which can test both the   headphone and microphone portion of the

headset.

 

 

 

Functions and Specifications of   Type 1600HM

 

The fundamental specification of Type 1600HM is the same as Type 1600H, please refer to Type 1600H

 

 

 

A.       Combination of instruments

Item

Type

Test objects

Composition

Left earphone

Right earphone

Microphone

1

1600HS

 

160A + 181 + 142ES (2 sets) + 142FS

2

1600HM

160A + 181 + 142ES (2 sets) + 142FS + 140M

 

Descriptions

1.       Model-160A Electroacoustic Analyzer

2.       Model-181 Headset Testing Controller

3.       Model-142ES Artificial Ear (IEC-318)

4.       Model-142FS Headset Test Fixture

5.       Model-140M Artificial Mouth

 

Note:2 sets of Model-142ES and Model-142FS are inseparable; user should buy all items  at one time.

 

B.       Functions

Type 1600HM or Type 1600HS has the entire testing items possessed by Type 1600H, it also has left and right earphone balance testing (Can set 7 freq. points for testing) and the microphone char. testing, fully automatic switching, automatic testing and auto judging Go / No-Go

Test items of the Headset Type 1600HS Type 1600HM
Left earphone or right earphone Frequency Response (20Hz ~ 20KHz) & Sensitivity

Polarity Test

AC Impedance Test ( 2 ~ 1000 Ohms )
DCR Test  ( 2 ~ 1000 Ohms )

Distortion Test

( 0.5% ~ 20% @ 0.1 ~ 10mW Adjustable )

Balance Test  (Can set 7 freq. points)

Mic. testing

Frequency Response (100Hz ~ 8KHz) & Sensitivity
ECM Current Test  ( 0mA ~ 3mA )

Distortion Test

( 1KHz ; 0.5% ~ 20% @ MRP 100dBSPL )

Supply voltage of ECM+0.9V ~ +9V adjustable
Loading resistor of ECM180 Ohms ~ 9 KOhms; adjustable

 

 