Type 1600T Transmitter Measuring System
Main Functions
1.
Electret condenser microphone (ECM), or transmitter using ECM.
2.
Dynamic, Piezo and Ceramic transmitters.
3. Type 1600T can be used to measure various general purpose microphones. Please
note that the measured results (including sensitivity and frequency response) are refer
to the condition of “Near Field” (35 mm from the artificial mouth). These results may
differ slightly from those measured under far field condition. The later condition is often
used to specify the characteristics of general purpose microphones.
It is proposed to use 1600M for the measurement of general purpose microphones. The measured results are refer to far field condition.
1600T can test speedy the frequency response, 1kHz sensitivity, 1KHz distortion, Current of ECM etc. characteristics of the aforementioned transmitter.
| Catalogue | Example of Testing Screen |
The fundamental combination of Type 1600T |
|||
Item |
Model No. |
Description | Usage |
1. |
160 A |
Electroacoustic Analyzer | Mainframe. To control and process the input、output signal. |
2. |
Monitor & Keyboard |
High Resolution Color Display Monitor & Keyboard |
Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax. |
3. |
167 |
R / T Testing Adapter |
Combines with 160 or 170 mainframe, to test the frequency response curve sensitivity & impedance 、 distortion etc. characteristics of the receiver and transmitter. |
4. |
140 M | Artificial Mouth |
Generates a flat and stable、precise sound field, for testing the “Transmitter". |
5. | ETF - 1 | Transmitter Test Fixture | Used to position the artificial mouth, to test the transmitter and condenser microphone. |
6. |
( Option ) |
Sorting Driver | Please refer to Note as below. |
7. | X-Y Mouse | Mouse | Replace the upward, downward, leftward, rightward and enter keys on the keyboard. |
8. |
HP Printer ( Option) |
Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.) |
Print out the tested results & data. |
Note : Model-186 Sorting Driver when combined for use with Model – 160A ( or Model – 184 ) mainframe and user’s automatic sorting machine, can perform the automatic sorting which totally can be divided into 14 ranks. The sensitivity sorting is divided into 12 ranks (which are the same as the number of rank for the sensitivity sorting on the testing screen); Frequency response ranked at 13th , while the other testing items, like : The impedance, distortion, ECM current etc. of the unqualified items ranked at 14th (When the indicators of the 1st~13th rank did not light up, it belongs to 14th rank). Model-186 is very suitable for use in the automation for the receiver, transmitter and microphone factories.
|
Functions and Specifications of Type 1600 T |
(1) 1
kHz sensitivity : Test range = .-
20 dB V /μbar
∼
-
110 dB V /μbar. =
0 dB V/Pa to -90 dB V/Pa. in
two ranges, automatically ranging. (2)
Frequency
response : Sweep
range can be set from any two frequencies between 100 Hz to 10 kHz,
the narrower the range and the faster the speed. The interval of
sampling frequency points can be set from 1/12 to
1/48 octave. The upper and lower limits of the frequency
response can be set by the user. “Best fit” or “1 kHz
normalization” method can be selected for the PASS/FAIL judgment of
frequency response. Two response curves can be stored (two colors) for
comparison purpose. The dB value of a curve at any frequency can be
read out. Test
speed : If
the instrument is set to 200 to 5 kHz, 1/12 octave, totally only 1.0
second is required for test its sensitivity at 1 kHz, frequency
response curve and judgment of PASS/FAIL. (3)
Distortion
at 1 kHz : One of the following
harmonic distortion can be selected: 2nd, 3rd, 2nd and 3rd, 2nd to
4th, 2nd to 5th, and THD. Measurable distortion range is from 0.2% to
20%. The upper limit can be set by the user for PASS/FAIL judgment.
The sound pressure level can be set by the user from 88 to 118 dB SPL
(-6dB Pa to +24 dB Pa).
Distortion
measurement should be carried out in an anechoic chamber or in a very
quiet room. However, sensitivity and frequency response can be
measured in noisy environment. (4)
ECM
current : Automatic testing the ECM
DC current, 0.001 to
3.000 mA, +/-(1.2%+0.002 mA). (5)
ECM
voltage supply : The
DCV is fed by Model-167. The open circuit voltage is ranging from 0.9
V to 9 V which can be set by the user. The set voltage is displayed on
screen. Tolerance
of voltage setting :
+/-(0.5%+0.01V) (6)
ECM
loading resistance :
Provided by Model - 167. The value can be
adjusted from the front panel, ranging from 0.2 k to 10 kΩ
+/-(1%+0.01kΩ).
The set value will also be displayed on screen. (7)
Statistics
: Statistic analysis of the number and
percentage of passed and failed products. (8)
Print
out : A
printer (option) can be connected to Type 160 to print out the test
report of above items 1 to 7. (9) Automatic judgment : The upper and lower limits can be set freely for above items 1 to 4. The instrument will check PASS/FAIL automatically and the result will be displayed on screen. The set limits are stored on disk so that next time it is not necessary to set the limits again. Different limits can be set & stored in different disks for other types of transmitters or microphones if required. (10) Automatic sorting : According to the measured sensitivity, several groups can be established (the number of group can be set by the user). The number and percentage of the measured objects in each group can be displayed and printed out. |
Products list | brand | Model No. | Home