Contact
2-Line V-LISN; Acc. to CISPR16-1 Spec
|
|
- |
Frequencyrange9kHz¡V30MHz |
- |
Impedance50£[//50£gH+5£[ |
- |
Insertionloss<2.0dB |
- |
Highpassfilter150kHz(connectible)5pol.,Chebycheff |
- |
Limiter136dB£gV(connectible) |
- |
Attenuator20dB/2W(connectible) |
- |
PE-Simulation50£gH/16air-corecoil(connectible |
- |
Powerrating2x16A(230V) |
- |
RemoteTTL-Level |
- |
Incl.Correctionvalues |
- |
Incl.CertificateofConformity |
Application
Within the range of the line-bounded interfering voltage measurement technique, the standard CISPR-16-1 demands measuring instruments which are simulating a reproducible impedance of the mains supply and are blocking disturbances out of the mains. Is a frequency range of 9 kHz to 30 MHz existing, a so-called LISN is required with a defined developing of impedance. |
Solution
For this purpose MTS Systemtechnik has developed a LISN which fulfills the requirements of the CISPR 16-1. This LISN has 2 phases with a maximum ampacity of 2x16A. |
Characteristics
- |
LISN according to CISPR, EN, VDE, ANSI |
- |
Operating voltage switchable (115/ 230V) |
- |
Frequency range 9 kHz to 30 MHz |
- |
19"-Table top case |
- |
Test connection through protection conductor socket |
- |
Remote controlable over TTL-levels |
- |
International style (G, GB, F, I, CH, USA) |
- |
Permanent current up to 2x 16A |
- |
Air-core coil |
- |
Calibrated according to CISPR 16-1:1999 |
- |
Small insertion loss |
|
|
|
|