Contact
4-Line V-LISN; Acc. to CISPR16-1 Spec
|
|
- |
Frequencyrange150kHz¡V30MHz |
- |
IImpedance50£gH//50£[ |
- |
IInsertionloss<2.0dB |
- |
Limiter140dB£gV(fixed) |
- |
Attenuator20dB/2W(fixed) |
- |
Operatingvoltage115/200VAC(DC-63Hz);230/400VAC(DC-63Hz) |
- |
Powerrating4x250A |
- |
Auxiliarycurrentsupply115/230V¡V60VAswitchable |
- |
RemoteTTL-Level |
- |
IIncl.Correctionvalues |
- |
Incl.CertificateofConformity |
Application
Within the range of the line-bounded interfering voltage measurement technique, the standard CISPR-16-1 demands measuring instruments which are simulating a reproducible impedance of the mains supply and are blocking disturbances out of the mains. Is a frequency range of 150 kHz to 30 MHz existing, a so-called LISN is required with a defined developing of impedance. |
Solution
For this purpose MTS Systemtechnik has developed a LISN which fulfills the requirements of the CISPR 16-1. This LISN has 4 phases with a maximum ampacity of 4x 250A. |
Characteristics
- |
LISN according to CISPR, EN, VDE, ANSI |
- |
Temperature control |
- |
Frequency range 150 kHz to 30 MHz |
- |
Integrated cooling |
- |
Permanent current up to 4x 250 A |
- |
Remote controlable over TTL-levels |
- |
Contact-voltage-proof high current connections |
- |
Calibrated according to CISPR 16-1:1999 |
- |
Air-core coil |
|
|
- |
Small insertion loss |
|
|
|
|