Type 1700 Telephone Analyzer

 

Main Functions

Can test the electrical characteristics of an analogue corded and cordless phone, PBX and the transformer :

The tested items varies according to different country standard, Like : Frequency Response and Loudness Rating of the receivingsending and Sidetone,  Harmonic Distortion, Return Loss, DCR, Loop Current, DC I-V, I-R, ON-HOOK Leakage Current, ON HOOK AC Impedance Curve , OFF HOOK AC Impedance Curve, Linearity or Amplitude response , Clipping Test , the Sensitivity and Frequency Response Curve of the H.A.C. Magnetic Field … etc.

Catalogue  |  Main  Features  |  Test  Items Accredited  |  Example of Test Screen

The fundamental combination of Type 1700

Item

Model No.

Description

Usage

1.

170 A

Telephone Analyzer

Mainframe. To control  and process the inputoutput signal.

2.

Monitor &Keyboard

High Resolution Color Display Monitor & Keyboard

Display the tested results & data and key in data. User may buy these two items at his local market, since price is cheaper and can save freight charge and import tax.

3.

147B

Test Head

Sets the test angle and position of the artificial ear and mouth, to test the acoustic characteristics of the handset.

4.

140M

Artificial Mouth

Generates a flat and stableprecise sound field, for testing the  Transmitter".

5.

142EA-S

or  142EK-S

Artificial Ear   ( 142EA = IEC - 318  ; 142EK-S = 6 c.c. Coupler ) 

Receives the sound generated from the receive.

6.

173 XXX

(or 163 XXX)

Artificial Line  ( 173 XXX )

or Terminator  ( 163 XXX )

The artificial line in accordance to the specified country standard from the Telecom to the client ‘s site. ( Country Standard press here )

7.

GM-2

Hearing Protection & R. Noise Measurement Set

Combine for use with the Model-170A mainframe , to test the characteristic for  the hearing protection and receiving residual noise of the telephone.

( See " Note " please )

9.

X-Y Mouse

Mouse

Replace the upward, downward, leftward, rightward and enter keys on the keyboard.

10.

HP Printer

( Option)

Printer (All the HP DeskJet or HP Laser Printers that are supported by DOS can all be used.)

Print out the tested results & data.

Note  : GM-2 is used for testing the hearing protection and receiving residual noise ,  Some countries like Germany, England, Australia  and New Zealand  etc. required this kind of testing, If  not require the testing for the hearing protection and receiving residual noise , then, GM-2 is not needed.

 

Functions and Specifications of   Type 1700

Feeding Bridge Voltage

Symmetric  Balanced Type. Voltage can be set from 573V ±( 0.4rdg 0.15FS ) 

Resolution: 0.1V, program-mable Software Setting.

 

Current : 0120 ma.

Accuracy: 02 ma±(2.5﹪+ 2ua)Resolution 1ua;  2120 ma ± ( 1.5﹪+0.1 ma  ).

 

ResistanceRtotRL1RL2Rv ;

RL1RL2150Ω=Resistance of the Inductor; RvResistance of the programmable Serial Resistor ; 

Rv =  02550Ω  (overall from 300Ω∼ 2850Ω, 10Ω /  Step) .

 

Coupling capacitor2u×2 , 4u×2 , 37u×2 , programmable and set automatically according  to specific standard. (see Note 3).

 

Sweep frequency range

In the range between 100 Hz10 KHz. The working range is deter-mined according to specific standard automati- cally, e.g.:180 Hz5 KHz  according to Taiwan, EIA or China Std., or 160 Hz8 KHz  according to BS6317 .

 

Resolution or interval of sweep frequencies: ( user  selectable )   Fast:1/12 oct.   Slow: 1/48 oct. ( continuous ) .

 

Test standardITU-T  (CCITT)EIA (IEEE)OREM  AOREM B  

 

Frequency response judgement : Mask ( Best Fit ) or   1KHz  Normalization method. Automatically  set According to specific standard.

 

Dynamic range of  freq. response meas. :  70 dB.

 

Sending test range10 ∼ -60 dBV

 

Receiving test range50 120 dB  SPL

 

Sidetone test range50 120 dB  SPL

 

Sound level from Artificial Mouth : 75 107dB SPL @ MRP.    Set by the  Software in step 0.1dB.

 

Artificial Line : 0 7.5 Km, 0.5 Km / Step ; or   0 15 Kft , 1 Kft / Step ( EIA ).

 

Electrical signal for  receiving testEMF =0.07V 3V,  set by the software in step 0.1dB, accuracy <±  (0.1 dB1mv).

 

Test range of RE or LR

EIA  CCITT OREM   A / B
TOLR 20 ∼ - 65 dB SLR    15∼+ 30 dB TRE:-20   ∼+ 25 dB
ROLR: +30∼+75 dB RLR   20∼+ 25 dB  RRE:-15  ∼+ 30 dB
SOLR 20 ∼+25 dB STMR:-10∼+ 35 dB SRE:-25    ∼+ 20 dB

 

Tighten or Loosen  of Upper / Lower limits range9.9∼+ 9.9 dB,  0.1dB/step.

 

Return Loss Measurement

Terminal ImpedanceInternal : 600Ω, 900Ω, and  3  different complex  impedance according to UK, China and Germany standards.

 

External : Three additional  Zext terminals are provided.Test range: 0 40 dB ( Note:> 40 dB is meaningless ),  

 

Accuracy : 300Hz4KHz ±  0.3dB @ 0 30 dB / ± 0.6dB @ 30 35 dB / ± 1dB @ 35 40 dB

 

Frequency rangeDetermined by specific std. ranging from 100 Hz 10 KHz .

 

Printer interface : HP or compatible.

 

Power90V240V, 4763Hz, 150VA max..

 

Weight & dimension N.W ( H )×( W )×( D )

MODEL170 9.5  Kgs. 17 × 36 × 39  CM

14"  MONITOR 11.5  Kgs. 37 × 35 × 39 CM

MODEL147 6.5  Kgs. 49 × 21 × 30 CM ( Test  Head )

Optional   Functions :

Type 1700 can  test  the  PBX PABXModem Receiver Transmitter ECM Transformer  for Communication

(a) With an optional  Model-172A , when combined with Type 1700, can test various characteristics of PBX

     PABXModem, including the Insertion  Loss Cross Talk (40 110dB)DistortionReturn Loss

     ImpedanceFrequency Response I-V Curves I-R Curves, High Test Speed.  

 

 

 (b) With an optional  Model-167 , when combined with Type 1700, can  test the ReceiverTransmitterFrequency

       Response of ECMImpedanceDistortortionSensitivityH.A.C. Magnetic Field of Receiver, High Test

       speed.  

 

 

(c) With an optional  Model-174 , when combined with Type 1700, can test the Frequency ResponseDistortion

     Insertion LossReturn Loss of theTransformer for Communication, also, user can test the above-mentioned various

     characteristics under the condition of DC current setting from  0 to 120 mA, High Test Speed.

 