Digital oscilloscope "ViewGoⅡ" DS-5400A series
DS-5400A series Frequency bandwidth 100-200MHz Maximum Sampling Speed 2GS/s (200MHz Type) Maximum Sampling Speed 1GS/s (100MHz Type) Input Channel 4 Maximum Memory Length 500kpts/ch |
DS-5400A series functions
Auto-measure for all cycles captured
All cycles captured from a waveform can be measured and
displayed automatically. By taking in the data into the high length memory,
you can observe the variability of Max/Min values and analyze the values from
the calculation between the cursor intervals of time axis. |
Probe selection function
When an Iwatsu probe model is selected, the attenuation ratio and the coupling are set automatically. The model number, the band width of Vertical range, and Input coupling are displayed after you selected the model. |
Skew function between channels
You
can adjust the skews between the channels. This function is useful, for
example, when you calculate the power waveform which is affected by timing. |
Clear sweep function
This function is used for Resetting the following
calculated data: |
Digital oscilloscope "ViewGoⅡ" DS-5400A series specification
DS-5424A |
DS-5422A |
DS-5414A |
DS-5412A |
|
Frequency band (-3dB) |
200MHz |
100MHz |
||
Rise time |
1.75ns |
3.5ns |
||
Number of input channels |
Four |
2 |
Four |
2 |
Maximum sampling rate |
2GS/s (when channels are combined), 1GS/s (when all channels are used) |
|||
Equivalent sampling rate |
100GS/s |
|||
Peak detection resolution |
1 ns |
|||
Averaging function |
2 to 256 times (power of 2) |
|||
Memory length |
500k points/ch (all channels) |
|||
Vertical resolution |
8 bits |
|||
Input voltage range |
2mV/div ~ 10V/div |
|||
Offset voltage |
2mV/div to 50mV/div: ±1V, 50.2mV/div to 500mV/div: ±10V, 502mV/div to 10V/div: ±100V |
|||
Deskew |
0 ~ 500 ns |
|||
DC gain accuracy |
± (1.5% + 0.5% full scale) |
|||
Maximum input voltage |
±400 Vpk |
|||
Band limiting filter |
Analog system: 20MHz, 2MHz, 200kHz |
|||
Input coupling |
GND, DC 1MΩ, AC 1MΩ |
|||
Input impedance |
1 MΩ ± 1.0% || 20 pF ± 2 pF (DC1 MΩ) |
|||
Probe sense |
Automatic
detection: 1:1、10:1、100:1、1000:1 |
|||
Time axis range |
2ns/div ~ 50s/div |
5ns/div ~ 50s/div |
||
Standard probe |
SS-0130R (Standard attachment for the number of channels) |
|||
Roll mode |
50ms/div ~ 50s/div (100kS/s max) |
|||
Clock accuracy |
±10 ppm |
|||
Trigger function |
||||
Trigger function |
Edge, number of pulses, pulse width, period, missing, TV |
|||
Trigger mode |
AUTO, NORMAL, SINGLE, STOP |
|||
TV trigger (standard) / |
NTSC, PAL, Custom / up to 3000 / 1, 2, 4, 8 |
|||
Pulse number trigger setting range |
1 to 9999 events |
|||
Pulse width trigger time setting range |
15ns ~ 50s |
|||
Period trigger time setting range |
40ns ~ 50s |
|||
Dropout |
50ns ~ 50s |
|||
Trigger source |
All channels, EXT (±0.5V), EXT10 (±5.0V), line |
|||
Trigger slope/coupling |
Positive, negative/AC, DC, high frequency rejection, low frequency rejection, noise rejection |
|||
Display/resolution |
||||
Display/resolution |
7.5-inch color TFT LCD (touch screen) / VGA: 640 × 480 pixels |
|||
Display format |
YT, XY, XY trigger |
|||
Vector connection |
Interpolation display between sample points, dot display |
|||
Analog persistence |
Monochromatic gradation display, spectrum display |
|||
Persistence display time |
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, infinity |
|||
Internal waveform storage |
5 waveforms |
|||
AUTO SETUP function |
Enabled/disabled configurable |
|||
Save front panel settings |
5 settings can be stored in the internal memory, USB memory |
|||
Parameter measurement, cursor, zoom, calculation, replay function |
||||
Parameter measurement |
Maximum value, minimum value, peak peak, RMS value, cycle RMS value, average value, cycle
average value, top, base, top-base, rising overshoot, falling overshoot,
rising time 20-80%, falling time 80-20%, rise time 10-90%, fall time 90-10%,
frequency, period, number of pulses (positive), number of pulses (negative), |
|||
Simultaneous measurement/statistical value display |
Maximum 4 parameters/maximum value, minimum value, number of measurements |
|||
cursor |
Time, amplitude, time & amplitude, cursor value |
|||
zoom |
Press the Zoom button on the front panel to display the enlarged waveform in another grid |
|||
Math function |
Addition,
subtraction, multiplication, FFT |
|||
Rescale/Unit conversion |
a*x+b (x: input voltage, a, b: user defined)/volt, ampere, watt, °C, no display |
|||
Replay |
Automatically record waveforms, save up to 1024 waveforms, replay possible |
|||
Frequency counter |
6 digits |
|||
interface |
USB 2.0 HS compatible (device, host), GPIB (factory option DS-576) |
|||
AUX interface |
External option connector |
|||
Save waveform data |
Save to USB memory in binary, ASCII, Mathcad, Math (ASCII), Math (Mathcad) |
|||
Hardcopy output |
Save to USB
memory in TIFF, BMP, PNG (transparency compatible) format |
|||
Calibration signal output |
Square wave 1kHz, 3Vp-p |
|||
Power/power consumption |
AC100~240Vrms(50/60Hz), AC100V~120V(400Hz) / 95VA(60W)max |
|||
Dimension/Mass weight |
About 330Wx190Hx124D mm / About 3.7kg |
|||
Environmental condition |
||||
Performance guarantee temperature |
10 ~ 35 ℃ |
|||
Operating temperature/humidity/altitude |
Temperature
0-40°C / Humidity 5-80%RH ≤ 30°C (no condensation), |
|||
Standard accessories |
||||
Probe (number of channels), power cord (1), front panel cover (1), instruction manual (CD-ROM) (1), user's guide (1) |
||||
option |
||||
GPIB interface |
GPIB: IEEE488.2 |
|||
Power supply for probe |
Two power supplies for our active probe |
Dedicated option
Digital oscilloscope "ViewGoⅡ" DS-5400A series option
DS-576 GP-IB interface |
|||||||||
DS-579 Probe power option
|
|||||||||
IE-1226 made to order VGA Video OUT option You can output the waveform screen to an external display. *DS-579 cannot be used after IE-1226 is installed. |
|||||||||
Carrying bag *Commercial item, multipurpose bag |
■ Standard probe
SS-0130R Frequency
bandwidth: DC to 200MHz |
■High voltage differential probe
Frequency
bandwidth: DC to 100MHz Standard price 99,800 yen (excluding tax) |
|
DS-579 Probe power option ViewGoⅡ dedicated probe power supply unit Compatible probes: SFP-5A/4A, SS-270/260/250/240A/240, SS-320 |
|
Power supply for SFP-5A/4A/SS-320 |
■ Active probe
Frequency
bandwidth: DC to 1 GHz (for probe only) |
|
Frequency
bandwidth: DC to 800MHz *1 |
|
DS-579 Probe power option ViewGoⅡ dedicated probe power supply unit Compatible probes: SFP-5A/4A, SS-270/260/250/240A/240, SS-320 |
|
Power supply for SFP-5A/4A/SS-320 |
■High voltage probe
PHV 1000-RO Attenuation
ratio: 100:1, Input RC: 50 MΩ 7.5 pF |
|
DC-50MHz, DC-30kV, pulse 40kV |
|
DC-50MHz, DC-60kV, pulse 80kV |
*Please select the high voltage probe after confirming the derating characteristics.
■ Current probe
Rogowski coil current probe SS-28xA series Frequency
band: fL to 30MHz Sensor part temperature range: -40℃ to 125℃ |
|
Rogowski coil current probe SS-29x series Frequency
band: S type-fL to 20MHz, L type-fL to 10MHz Sensor part temperature range: -40℃ to 125℃ |
|
Frequency bandwidth: DC to 100MHz *1 (maximum 30Arms) |
|
Frequency bandwidth: DC to 50MHz *1 (max. 30Arms) |
|
Frequency bandwidth: DC to 10MHz *1 (up to 150Arms) |
|
Frequency bandwidth: DC to 2MHz *1 (maximum 500Arms) |
|
DS-579 Probe power option ViewGoII series dedicated probe power supply unit Compatible probe: SFP-5A/4A, SS-270/260/250/240A/240 |
|
Power supply for current probe |
*1 For a single probe
* Calibration certificate, traceability system diagram, and inspection report will be charged separately.